RESEARCH / DISCOVERY
← Back to the library

The Utility of Breath Analysis in the Diagnosis and Staging of Parkinson's Disease.

The Utility of Breath Analysis in the Diagnosis and Staging of Parkinson's Disease.

Read the original publication

Where did the research take place?

Possible study sites were matched from the text; these need review.

Time, NO · Possible study site

METHODS: Breath samples were collected from 177 people with PD and 37 healthy matched control individuals followed over time.
Location evidence

Same, TZ · Possible study site

Standard clinical data (MDS-UPDRS & cognitive assessments) from the PD patients were collected at the same time as the breath sample was taken, these measures were then correlated with the breath test analysis of exhaled VOCs.
Location evidence

Cambridge, GB · Author affiliation

John van Geest Centre for Brain Repair, Department of Clinical Neuroscience, University of Cambridge, Forvie Site, Cambridge, UK.
Location evidence

Haifa, IL · Author affiliation

Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: The analysis of volatile organic compounds (VOCs) collected in breath samples has the potential to be a rapid, non-invasive test to aid in the clinical diagnosis and tracking of chronic conditions such as Parkinson's disease (PD). OBJECTIVE: To assess the feasibility and utility of breath sample analysis done, both at point of collection in clinic and when sent away to be analyzed remotely, to diagnose, stratify and monitor disease course in a moderately large cohort of patients with PD. METHODS: Breath samples were collected from 177 people with PD and 37 healthy matched control individuals followed over time. Standard clinical data (MDS-UPDRS & cognitive assessments) from the PD patients were collected at the same time as the breath sample was taken, these measures were then correlated with the breath test analysis of exhaled VOCs. RESULTS: The breath test was able to distinguish patients with PD from healthy control participants and correlated with disease stage. The off-line system (remote analysis) gave good results with overall classification accuracies across a range of clinical measures of between 73.6% to 95.6%. The on-line (in clinic) system showed comparable results but with lower levels of correlation, varying between 33.5% to 82.4%. Chemical analysis identified 29 potential molecules that were different and which may relate to pathogenic pathways in PD. CONCLUSION: Breath analysis shows potential for PD diagnostics and monitoring. Both off-line and on-line sensor systems were easy to do and provided comparable results which will enable this technique to be easily adopted in clinic if larger studies confirm our findings.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE