RESEARCH / DISCOVERY
← Back to the library

Simultaneously Detecting Monoamine Oxidase A and B in Disease Cell/Tissue Samples Using Paper-Based Devices.

Simultaneously Detecting Monoamine Oxidase A and B in Disease Cell/Tissue Samples Using Paper-Based Devices.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Nanjing, CN · Author affiliation

Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China.
Location evidence

CN · Author affiliation · country only

Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

As enzymes in the outer membrane of the mitochondrion, monoamine oxidases (MAOs) can catalyze the oxidative deamination of monoamines in the human body. According to different substrates, MAOs can be divided into MAO-A and MAO-B. The imbalance of the MAO-A is associated with neurological degeneration, while excess MAO-B activity is closely connected with Parkinson's disease (PD) and Alzheimer's disease (AD); therefore, detection of MAOs is of great significance for the diagnosis and treatment of these diseases. This work reports the multiplexed detection of MAO-A and MAO-B using paper-based devices based on chemiluminescence (CL). The detection limits were 5.01 pg/mL for MAO-A and 8.50 pg/mL for MAO-B in human serum. In addition, we used paper-based devices to detect MAOs in human cells and tissue samples and found that the results of paper-based detection and Western blotting (WB) showed the same trend. While only one antibody can be incubated on the same membrane by WB, multiple antibodies incubated on the same paper enabled simultaneous detection of MAO-A and MAO-B by paper-based devices. The paper-based assay could be used for preliminary early screening of clinical samples for MAOs and can be extended as an alternative to WB for multiplexed detection of various proteins in disease cell or tissue samples.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE