RESEARCH / DISCOVERY
← Back to the library

Predicting Fall Counts Using Wearable Sensors: A Novel Digital Biomarker for Parkinson's Disease.

Predicting Fall Counts Using Wearable Sensors: A Novel Digital Biomarker for Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Dublin, IE · Author affiliation

Kinesis Health Technologies Ltd., D04 V2N9 Dublin, Ireland.
Location evidence

Copenhagen, DK · Author affiliation

Biomarker Department, Division of Experimental Medicine, H. Lundbeck A/S, 2500 Copenhagen, Denmark.
Location evidence

London, GB · Author affiliation

Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London SE5 9RX, UK.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

People with Parkinson's disease (PD) experience significant impairments to gait and balance; as a result, the rate of falls in people with Parkinson's disease is much greater than that of the general population. Falls can have a catastrophic impact on quality of life, often resulting in serious injury and even death. The number (or rate) of falls is often used as a primary outcome in clinical trials on PD. However, falls data can be unreliable, expensive and time-consuming to collect. We sought to validate and test a novel digital biomarker for PD that uses wearable sensor data obtained during the Timed Up and Go (TUG) test to predict the number of falls that will be experienced by a person with PD. Three datasets, containing a total of 1057 (671 female) participants, including 71 previously diagnosed with PD, were included in the analysis. Two statistical approaches were considered in predicting falls counts: the first based on a previously reported falls risk assessment algorithm, and the second based on elastic net and ensemble regression models. A predictive model for falls counts in PD showed a mean R2 value of 0.43, mean error of 0.42 and a mean correlation of 30% when the results were averaged across two independent sets of PD data. The results also suggest a strong association between falls counts and a previously reported inertial sensor-based falls risk estimate. In addition, significant associations were observed between falls counts and a number of individual gait and mobility parameters. Our preliminary research suggests that the falls counts predicted from the inertial sensor data obtained during a simple walking task have the potential to be developed as a novel digital biomarker for PD, and this deserves further validation in the targeted clinical population.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE