RESEARCH / DISCOVERY
← Back to the library

Technical validation of real-world monitoring of gait: a multicentric observational study.

Technical validation of real-world monitoring of gait: a multicentric observational study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Sheffield, GB · Author affiliation

INSIGNEO Institute for in silico Medicine, The University of Sheffield, Sheffield, UK c.mazza@sheffield.ac.uk.
Location evidence

Newcastle upon Tyne, GB · Author affiliation

Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK.
Location evidence

Lausanne, CH · Author affiliation

Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.
Location evidence

Stuttgart, DE · Author affiliation

Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.
Location evidence

Sassari, IT · Author affiliation

Department of Biomedical Sciences, University of Sassari, Sassari, Sardegna, Italy.
Location evidence

Tel Aviv, IL · Author affiliation

Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Location evidence

Barcelona, ES · Author affiliation

ISGlobal, Barcelona, Spain.
Location evidence

Madrid, ES · Author affiliation

CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.
Location evidence

Turin, IT · Author affiliation

Dipartimento di Elettronica e Telecomunicazioni, Politecnico di Torino, Torino, Italy.
Location evidence

Dublin, IE · Author affiliation

Insight Centre for Data Analytics, O'Brien Science Centre, University College Dublin, Dublin, Ireland.
Location evidence

Bologna, IT · Author affiliation

Department of Electrical, Electronic and Information Engineering «Guglielmo Marconi», University of Bologna, Bologna, Italy.
Location evidence

Erlangen, DE · Author affiliation

Machine Learning and Data Analytics Lab, Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Location evidence

NL · Author affiliation · country only

McRoberts BV, Den Haag, Zuid-Holland, Netherlands.
Location evidence

Kiel, DE · Author affiliation

Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.
Location evidence

Trondheim, NO · Author affiliation

Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.
Location evidence

Basel, CH · Author affiliation

Novartis Institutes of Biomedical Research, Novartis Pharma AG, Basel, Switzerland.
Location evidence

Södertälje, SE · Author affiliation

Digital Health R&D, AstraZeneca Sweden, Sodertalje, Sweden.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real-world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users' perspective on the device. METHODS AND ANALYSIS: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs.After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson's disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users' perspective on the deployed technology and relevance of the mobility assessment. ETHICS AND DISSEMINATION: The study has been granted ethics approval by the centre's committees (London-Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of Tübingen and of the University of Kiel). Data and algorithms will be made publicly available. TRIAL REGISTRATION NUMBER: ISRCTN (12246987).

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE