Validation of a Sensor-Based Gait Analysis System with a Gold-Standard Motion Capture System in Patients with Parkinson's Disease.

Validation of a Sensor-Based Gait Analysis System with a Gold-Standard Motion Capture System in Patients with Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

DE · Author affiliation · country only

Movement and Gait Lab, Sana-Krankenhaus Rummelsberg, 90592 Schwarzenbruck, Germany.
Location evidence

Erlangen, DE · Author affiliation

Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91052 Erlangen, Germany.
Location evidence

Luxembourg, LU · Author affiliation

Digital Medicine, University of Luxembourg, 4365 Esch-sur-Alzette, Luxembourg.
Location evidence

Esch-sur-Alzette, LU · Author affiliation

Digital Medicine, University of Luxembourg, 4365 Esch-sur-Alzette, Luxembourg.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Digital technologies provide the opportunity to analyze gait patterns in patients with Parkinson's Disease using wearable sensors in clinical settings and a home environment. Confirming the technical validity of inertial sensors with a 3D motion capture system is a necessary step for the clinical application of sensor-based gait analysis. Therefore, the objective of this study was to compare gait parameters measured by a mobile sensor-based gait analysis system and a motion capture system as the gold standard. Gait parameters of 37 patients were compared between both systems after performing a standardized 5 × 10 m walking test by reliability analysis using intra-class correlation and Bland-Altman plots. Additionally, gait parameters of an age-matched healthy control group (n = 14) were compared to the Parkinson cohort. Gait parameters representing bradykinesia and short steps showed excellent reliability (ICC > 0.96). Shuffling gait parameters reached ICC > 0.82. In a stridewise synchronization, no differences were observed for gait speed, stride length, stride time, relative stance and swing time (p > 0.05). In contrast, heel strike, toe off and toe clearance significantly differed between both systems (p < 0.01). Both gait analysis systems distinguish Parkinson patients from controls. Our results indicate that wearable sensors generate valid gait parameters compared to the motion capture system and can consequently be used for clinically relevant gait recordings in flexible environments.