Original abstract

BACKGROUND: Step quantification is a good way to characterize the mobility and functional status of individuals with some functional disorder. Therefore, a validation study may lead to the feasibility of devices to stimulate an increase in the number of steps and physical activity level of individuals with Parkinson's Disease (PD). AIM: To investigate the validity of mHealth devices to estimate the number of steps in individuals with PD and compare the estimate with a standard criterion measure. METHOD: An observational study in a university laboratory with 34 individuals with idiopathic PD. The number of steps was measured using mHealth devices (Google Fit, Health, STEPZ, Pacer, and Fitbit INC®), and compared against a criterionstandard measure during the Two-Minute Walk Test using habitual speed. RESULTS: Our sample was 82% men with a Hoehn and Yahr mean of 2.3 ± 1.3 and mean walking speed of 1.2 ± 0.2 m/s. Positive and statistically significant associations were found between Google Fit (r = 0.92; p < 0.01), STEPZ (r = 0.91; p < 0.01), Pacer (r = 0.77; p < 0.01), Health (r = 0.54; p < 0.01), and Fitbit Inc® (r = 0.82; p < 0.01) with the criterion-standard measure. CONCLUSIONS: GoogleFit, STEPZ, Fitbit Inc.®, Pacer, and Health are valid instruments to measure the number of steps over a given period of time with moderate to high correlation with the criterion-standard in individuals with PD. This result shows that technology such as smartphone applications and activity monitor can be used to assess the number of steps in individuals with PD, and allows the possibility of using this technology for assessment and intervention purposes.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE