Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's disease.
Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
US · Author affiliation · country only
Department of Physical Therapy, University of Alabama at Birmingham School of Health Professions, 360, 1720 2nd Ave S, Birmingham, AL 35233, United States. Electronic address: bjeng@uab.edu.Location evidence
Uberaba, BR · Author affiliation
Graduate Program in Physical Education, Graduate Program in Physical Education, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Persons with Parkinson's disease (PD) participate in low levels of physical activity. This has prompted interest in developing interventions targeting physical activity behavior in PD. However, the current cut-points to quantify moderate-to-vigorous physical activity (MVPA) developed for PD have been derived from a single, vertical axis using hip-worn accelerometers, and this cut-point may not be applicable for wrist-worn devices. Wrist-worn devices might improve accessibility and compliance with physical activity monitoring in PD. RESEARCH QUESTION: What is the relationship between wrist-based activity counts and energy expenditure during treadmill walking in persons with PD? Do cut-points for quantifying time spent in MVPA differ between persons with PD and controls matched by age and sex? METHODS: The sample included 26 persons with mild-to-moderate PD (Hoehn and Yahr stages 2-3) and 27 age- and sex-matched controls. Participants completed three, 6-minute bouts of walking on a treadmill at three increasing speeds. Vector magnitude was measured using ActiGraph GT3X+ accelerometer worn on the more affected side for persons with PD and the non-dominant side for controls. The rate of oxygen consumption, or energy expenditure, was measured using a portable, open-circuit spirometry system. RESULTS: Our results indicated a strong association between activity counts and energy expenditure for persons with PD and controls with R2 values of 0.94(0.07) and 0.95(0.06), respectively. Persons with PD had a cut-point of 2883(871) counts·min-1; this was significantly lower than the cut-point of 4389(1844) counts·min-1 for controls. CONCLUSION: We generated a PD-specific cut-point for wrist-worn ActiGraph accelerometers among persons with PD, and this was lower than controls. This disease-specific cut-point may provide more accurate measurements of time spent in MVPA in PD.