RESEARCH / DISCOVERY
← Back to the library

Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's disease.

Wrist-based accelerometer cut-points for quantifying moderate-to-vigorous intensity physical activity in Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

US · Author affiliation · country only

Department of Physical Therapy, University of Alabama at Birmingham School of Health Professions, 360, 1720 2nd Ave S, Birmingham, AL 35233, United States. Electronic address: bjeng@uab.edu.
Location evidence

Uberaba, BR · Author affiliation

Graduate Program in Physical Education, Graduate Program in Physical Education, Federal University of Triângulo Mineiro, Uberaba, Minas Gerais, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Persons with Parkinson's disease (PD) participate in low levels of physical activity. This has prompted interest in developing interventions targeting physical activity behavior in PD. However, the current cut-points to quantify moderate-to-vigorous physical activity (MVPA) developed for PD have been derived from a single, vertical axis using hip-worn accelerometers, and this cut-point may not be applicable for wrist-worn devices. Wrist-worn devices might improve accessibility and compliance with physical activity monitoring in PD. RESEARCH QUESTION: What is the relationship between wrist-based activity counts and energy expenditure during treadmill walking in persons with PD? Do cut-points for quantifying time spent in MVPA differ between persons with PD and controls matched by age and sex? METHODS: The sample included 26 persons with mild-to-moderate PD (Hoehn and Yahr stages 2-3) and 27 age- and sex-matched controls. Participants completed three, 6-minute bouts of walking on a treadmill at three increasing speeds. Vector magnitude was measured using ActiGraph GT3X+ accelerometer worn on the more affected side for persons with PD and the non-dominant side for controls. The rate of oxygen consumption, or energy expenditure, was measured using a portable, open-circuit spirometry system. RESULTS: Our results indicated a strong association between activity counts and energy expenditure for persons with PD and controls with R2 values of 0.94(0.07) and 0.95(0.06), respectively. Persons with PD had a cut-point of 2883(871) counts·min-1; this was significantly lower than the cut-point of 4389(1844) counts·min-1 for controls. CONCLUSION: We generated a PD-specific cut-point for wrist-worn ActiGraph accelerometers among persons with PD, and this was lower than controls. This disease-specific cut-point may provide more accurate measurements of time spent in MVPA in PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE