RESEARCH / DISCOVERY
← Back to the library

Prevalence of distinct types of hardware failures related to deep brain stimulation.

Prevalence of distinct types of hardware failures related to deep brain stimulation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Uberlândia, BR · Author affiliation

Centre for Innovation and Technology Assessment in Health, Faculty of Electrical Engineering, Postgraduate Program in Electrical and Biomedical Engineering, Federal University of Uberlândia, Campus Santa Mônica - Bloco 1E, Av. Joao Naves de Avila, 2121, Uberlandia, MG, 38408-100, Brazil.
Location evidence

Goiás, BR · Author affiliation

Bioengineering and Biomechanics Laboratory, Federal University of Goiás, Goiânia, Brazil.
Location evidence

Goiânia, BR · Author affiliation

Bioengineering and Biomechanics Laboratory, Federal University of Goiás, Goiânia, Brazil.
Location evidence

Niterói, BR · Author affiliation

Postgraduate Program in Neurology, Faculty of Medicine, Federal University of Fluminense, Niterói, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Deep brain stimulation (DBS) is an effective treatment of several types of neurological conditions, including Parkinson's disease, essential tremor, dystonia, and epilepsy. Despite technological progress in the past 10 years, the number of studies reporting side effects of DBS has increased, mainly due to hardware failures. This review investigated studies published between 2017 and 2021 to identify the prevalence of distinct types of hardware failures related to DBS. In total, fifteen studies were selected for the estimate of the prevalence of five distinct types of hardware failures: high impedance, fracture or failure of the lead or other parts of the implant, skin erosion and infection, lead malposition or migration, and implantable pulse generator (IPG) malfunction. The quality evaluation of the studies suggests a need to report results including populations from distinct regions of the world so that results can be generalized. The objective analysis of the prevalence of hardware failures showed that skin erosion and infection presented the highest prevalence in relation to other hardware failures. Despite the sophistication of the surgical technique of DBS over time, there is a considerable complication rate, about 7 per 100 individuals ([Formula: see text], in which CI is the confidence interval). Future research can also include correlation analysis with the aim of understanding the correlation between distinct hardware failures and variables such as gender, type of disorder, and age.