RESEARCH / DISCOVERY
← Back to the library

The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces.

The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Berlin, DE · Author affiliation

Movement Disorder and Neuromodulation Unit, Department of Neurology, Charité - Universitätsmedizin Berlin, Chariteplatz 1, 10117, Berlin, Germany. Electronic address: julian.neumann@charite.de.
Location evidence

Oxford, GB · Author affiliation

MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, United Kingdom.
Location evidence

Hannover, DE · Author affiliation

Department of Neurosurgery, Medizinische Hochschule Hannover, Hannover, Germany.
Location evidence

Leiden, NL · Author affiliation

Department of Neurology, Leiden University Medical Center, Leiden, the Netherlands; Department of Neurology, Haga Teaching Hospital, The Hague, the Netherlands.
Location evidence

The Hague, NL · Author affiliation

Department of Neurology, Leiden University Medical Center, Leiden, the Netherlands; Department of Neurology, Haga Teaching Hospital, The Hague, the Netherlands.
Location evidence

Prague, CZ · Author affiliation

Department of Neurology, Charles University, 1st Faculty of Medicine and General University Hospital, Prague, Czech Republic.
Location evidence

Bern, CH · Author affiliation

Department of Neurology, Bern University Hospital and University of Bern, Bern, Switzerland.
Location evidence

Würzburg, DE · Author affiliation

Department of Neurology, University Hospital of Würzburg and Julius Maximilian University of Würzburg, Würzburg, Germany.
Location evidence

San Francisco, US · Author affiliation

Department of Neurology, University of California, San Francisco, San Francisco, CA, 94143, USA.
Location evidence

Boston, US · Author affiliation

Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Brain sensing devices are approved today for Parkinson's, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatments unreliable. Therefore, clinicians need to understand how surgical decisions may affect artifact probability. OBJECTIVES: Investigate neural signal contamination with ECG activity in sensing enabled neurostimulation systems, and in particular clinical choices such as implant location that impact signal fidelity. METHODS: Electric field modeling and empirical signals from 85 patients were used to investigate the relationship between implant location and ECG contamination. RESULTS: The impact on neural recordings depends on the difference between ECG signal and noise floor of the electrophysiological recording. Empirically, we demonstrate that severe ECG contamination was more than 3.2x higher in left-sided subclavicular implants (48.3%), when compared to right-sided implants (15.3%). Cranial implants did not show ECG contamination. CONCLUSIONS: Given the relative frequency of corrupted neural signals, we conclude that implant location will impact the ability of brain sensing devices to be used for "closed-loop" algorithms. Clinical adjustments such as implant location can significantly affect signal integrity and need consideration.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE