The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces.
The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Berlin, DE · Author affiliation
Movement Disorder and Neuromodulation Unit, Department of Neurology, Charité - Universitätsmedizin Berlin, Chariteplatz 1, 10117, Berlin, Germany. Electronic address: julian.neumann@charite.de.Location evidence
Oxford, GB · Author affiliation
MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, United Kingdom.Location evidence
Hannover, DE · Author affiliation
Department of Neurosurgery, Medizinische Hochschule Hannover, Hannover, Germany.Location evidence
Leiden, NL · Author affiliation
Department of Neurology, Leiden University Medical Center, Leiden, the Netherlands; Department of Neurology, Haga Teaching Hospital, The Hague, the Netherlands.Location evidence
The Hague, NL · Author affiliation
Department of Neurology, Leiden University Medical Center, Leiden, the Netherlands; Department of Neurology, Haga Teaching Hospital, The Hague, the Netherlands.Location evidence
Prague, CZ · Author affiliation
Department of Neurology, Charles University, 1st Faculty of Medicine and General University Hospital, Prague, Czech Republic.Location evidence
Bern, CH · Author affiliation
Department of Neurology, Bern University Hospital and University of Bern, Bern, Switzerland.Location evidence
Würzburg, DE · Author affiliation
Department of Neurology, University Hospital of Würzburg and Julius Maximilian University of Würzburg, Würzburg, Germany.Location evidence
San Francisco, US · Author affiliation
Department of Neurology, University of California, San Francisco, San Francisco, CA, 94143, USA.Location evidence
Boston, US · Author affiliation
Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Brain sensing devices are approved today for Parkinson's, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatments unreliable. Therefore, clinicians need to understand how surgical decisions may affect artifact probability. OBJECTIVES: Investigate neural signal contamination with ECG activity in sensing enabled neurostimulation systems, and in particular clinical choices such as implant location that impact signal fidelity. METHODS: Electric field modeling and empirical signals from 85 patients were used to investigate the relationship between implant location and ECG contamination. RESULTS: The impact on neural recordings depends on the difference between ECG signal and noise floor of the electrophysiological recording. Empirically, we demonstrate that severe ECG contamination was more than 3.2x higher in left-sided subclavicular implants (48.3%), when compared to right-sided implants (15.3%). Cranial implants did not show ECG contamination. CONCLUSIONS: Given the relative frequency of corrupted neural signals, we conclude that implant location will impact the ability of brain sensing devices to be used for "closed-loop" algorithms. Clinical adjustments such as implant location can significantly affect signal integrity and need consideration.