RESEARCH / DISCOVERY
← Back to the library

Operation of the percutaneous endoscopic gastrostomy-jejunostomy tube without endoscopy in patients with Parkinson's disease on levodopa-carbidopa intestinal gel infusion therapy.

Operation of the percutaneous endoscopic gastrostomy-jejunostomy tube without endoscopy in patients with Parkinson's disease on levodopa-carbidopa intestinal gel infusion therapy.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

JP · Author affiliation · country only

Department of Neurology, National Center Hospital, Parkinson's Disease & Movement Disorders Center, National Center of Neurology and Psychiatry, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Tube-related adverse events (AEs) occur frequently in patients with Parkinson's disease (PD) receiving levodopa-carbidopa intestinal gel therapy. Endoscopy has become evasive since the beginning of the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to evaluate methods that use the percutaneous endoscopic gastrostomy-jejunostomy (PEG-J) tubes without endoscopy. METHODS: We included 19 patients in this study. The contrast agent was injected into the PEG-J tube to clarify the AEs related to the use of the tube. When the kink of the PEG-J tube was found, it was pulled approximately 5-10 cm. When placing or replacing the PEG-J tube, the percutaneous endoscopic gastrostomy (PEG) tube was pushed into the gastrostomy hole to bring its tip closer to the pylorus before a new PEG-J tube was inserted into it. RESULTS: The mean patient age was 63.1 ± 9.9 years, while the mean duration of PD was 16.7 ± 6.3 years. Tube-related AEs included PEG-J tube kinks (32 events), connector failures (20 events), and PEG-J tube entanglements without/with bezoars (9 events/5 events). All PEG-J tube kinks were resolved by tube manipulation with a fluoroscopic guide. In 66 of 85 events (77.6%), the PEG-J tube was placed or replaced without endoscopy. We believe that the use of the antispasmodic agent just before PEG-J operation reduced this rate. CONCLUSION: Our methods were able to resolve most AEs associated with PEG-J tube use without endoscopy.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE