RESEARCH / DISCOVERY
← Back to the library

Wearable Technology to Detect Motor Fluctuations in Parkinson's Disease Patients: Current State and Challenges.

Wearable Technology to Detect Motor Fluctuations in Parkinson's Disease Patients: Current State and Challenges.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Universidad, ES · Author affiliation

Programa en Ingeniería Biomédica (PhD), ETSI Telecomunicación, Universidad Politécnica de Madrid (UPM), Avenida Complutense, 30, 28040 Madrid, Spain.
Location evidence

Madrid, ES · Author affiliation

Programa en Ingeniería Biomédica (PhD), ETSI Telecomunicación, Universidad Politécnica de Madrid (UPM), Avenida Complutense, 30, 28040 Madrid, Spain.
Location evidence

Centro, ES · Author affiliation

Centro de Estudios e Innovación en Gestión del Conocimiento (CEIEC), Universidad Francisco de Vitoria, 28223 Pozuelo de Alarcón, Spain.
Location evidence

Pozuelo de Alarcón, ES · Author affiliation

Centro de Estudios e Innovación en Gestión del Conocimiento (CEIEC), Universidad Francisco de Vitoria, 28223 Pozuelo de Alarcón, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Monitoring of motor symptom fluctuations in Parkinson's disease (PD) patients is currently performed through the subjective self-assessment of patients. Clinicians require reliable information about a fluctuation's occurrence to enable a precise treatment rescheduling and dosing adjustment. In this review, we analyzed the utilization of sensors for identifying motor fluctuations in PD patients and the application of machine learning techniques to detect fluctuations. The review process followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Ten studies were included between January 2010 and March 2021, and their main characteristics and results were assessed and documented. Five studies utilized daily activities to collect the data, four used concrete scenarios executing specific activities to gather the data, and only one utilized a combination of both situations. The accuracy for classification was 83.56-96.77%. In the studies evaluated, it was not possible to find a standard cleaning protocol for the signal captured, and there is significant heterogeneity in the models utilized and in the different features introduced in the models (using spatiotemporal characteristics, frequential characteristics, or both). The two most influential factors in the good performance of the classification problem are the type of features utilized and the type of model.