The impact of tube replacement timing during LCIG therapy on PEG-J associated adverse events: a retrospective multicenter observational study.
The impact of tube replacement timing during LCIG therapy on PEG-J associated adverse events: a retrospective multicenter observational study.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Kawaminami, JP · Author affiliation
Department of Gastroenterological Surgery, Seizan-Kai Kawaminami Hospital, Kawaminami-cho, Kawaminami 18150-47, Koyu-gun, Miyazaki, 889-1301, Japan. kanefumi0519@yahoo.co.jp.Location evidence
Miyazaki, JP · Author affiliation
Department of Gastroenterological Surgery, Seizan-Kai Kawaminami Hospital, Kawaminami-cho, Kawaminami 18150-47, Koyu-gun, Miyazaki, 889-1301, Japan. kanefumi0519@yahoo.co.jp.Location evidence
Tokyo, JP · Author affiliation
Department of Gastroenterology and Minimally Invasive Surgery, Juntendo University Hospital, Tokyo, Japan.Location evidence
JP · Author affiliation · country only
Department of Gastroenterology, Fukui Red Cross Hospital, Fukui, Japan.Location evidence
Yokohama, JP · Author affiliation
Division of Endoscopy, Yokohama City University Medical Center, Kanagawa, Japan.Location evidence
Saitama, JP · Author affiliation
Department of Gastroenterology, Saitama Medical Center, Jichi Medical University, Saitama, Japan.Location evidence
Nagoya, JP · Author affiliation
Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan.Location evidence
Matsuyama, JP · Author affiliation
Department of Internal Medicine, Saiseikai Matsuyama Hospital, Ehime, Japan.Location evidence
Fukuoka, JP · Author affiliation
Department of Neurology, Fukuoka University, Fukuoka, Japan.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Levodopa-carbidopa intestinal gel (LCIG) treatment, a unique drug delivery system for patients with advanced Parkinson's disease (PD), is covered by health insurance in Japan since September 2016. Various LCIG procedure/device-associated adverse events (AEs) have been reported; however, reports on their treatment have been limited. This is the first multicenter study to clarify the frequency and timing of device-related AEs. METHODS: Between September 2016 and December 2018, 104 patients introduced to the LCIG treatment for advanced PD in 11 hospitals were included. The patients' characteristics, AEs incidence, AEs time, and tube exchange time were investigated. RESULTS: The median follow-up period was 21.5 months. Minor AE cases were 29.4%, whereas major AE cases were 43.1%. Majority of major AEs (n = 55, 94.8%) were managed with endoscopic treatment, such as tube exchange. Few severe AEs required surgical treatment (n =3, 5.2%). The mean (range) exposure to percutaneous endoscopic gastrojejunostomy (PEG-J) was 14.7 (0-33) months. One year after the LCIG treatment introduction, 55 patients (54.0%) retained the original PEG-J tube. The mean PEG-J tube exchange time was 10.8 ± 7.0 months in all patients, 11.6 ± 4.7 and 10.5 ± 7.7 months in patients with scheduled exchange and who underwent exchange due to AEs, respectively. CONCLUSIONS: Some device-related AEs occurred during the LCIG treatment; however, only few were serious, most of which could be treated with simple procedures or tube replacement with endoscopy. Therefore, the LCIG treatment is feasible and safe and is a unique treatment option for PD, requiring endoscopists' understanding and cooperation.