RESEARCH / DISCOVERY
← Back to the library

Rapid immunohistological measurement of tyrosine hydroxylase in rat midbrain by near-infrared instrument-based detection.

Rapid immunohistological measurement of tyrosine hydroxylase in rat midbrain by near-infrared instrument-based detection.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

US · Author affiliation · country only

University of South Carolina School of Medicine Greenville, 607 Grove Road, Greenville, SC, USA. Electronic address: sonne@greenvillemed.sc.edu.
Location evidence

Orlando, US · Author affiliation

College of Health Professions and Sciences, University of Central Florida, Orlando, FL, USA.
Location evidence

Valencia, US · Author affiliation

College of Health Professions and Sciences, University of Central Florida, Orlando, FL, USA; Science Department, Valencia College, Orlando, FL, USA. Electronic address: jasonsgroshong@gmail.com.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

We present a robust, fresh-frozen approach to immunohistochemistry (IHC), without committing the tissue to IHC via fixation and cryopreservation while maintaining long-term storage, using LiCor-based infrared (IR) quantification for sensitive assessment of TH in immunoreacted midbrain sections for quantitative comparison across studies. In fresh-frozen tissue stored up to 1 year prior to IHC reaction, we found our method to be highly sensitive to rotenone treatment in 3-month-old Sprague-Dawley rats, and correlated with a significant decline in rotarod latency-to-fall measurement by approximately 2.5 fold. The measured midbrain region revealed a 31 % lower TH signal when compared to control (p < 0.01 by t test, n = 5). Bivariate analysis of integrated TH counts versus rotarod latency-to-fall indicates a positive slope and modest but significant correlation of R2 = 0.68 (p < 0.05, n = 10). These results indicate this rapid, instrument-based quantification method by IR detection successfully quantifies TH levels in rat brain tissue, while taking only 5 days from euthanasia to data output. This approach also allows for the identification of multiple targets by IHC with the simultaneous performance of downstream molecular analysis within the same animal tissue, allowing for the use of fewer animals per study.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE