RESEARCH / DISCOVERY
← Back to the library

Complications associated with deep brain stimulation for Parkinson's disease: a MAUDE study.

Complications associated with deep brain stimulation for Parkinson's disease: a MAUDE study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Hempstead, US · Author affiliation

Department of Neurological Surgery, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA.
Location evidence

JE · Author affiliation · country only

Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA.
Location evidence

US · Author affiliation · country only

Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA.
Location evidence

Atlanta, US · Author affiliation

Department of Neurosurgery, Emory University School of Medicine, Atlanta, GA, USA.
Location evidence

San Diego, US · Author affiliation

Division of Neurosurgery, University of California San Diego School of Medicine, La Jolla, CA, USA.
Location evidence

La Jolla, US · Author affiliation

Division of Neurosurgery, University of California San Diego School of Medicine, La Jolla, CA, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Deep brain stimulation (DBS) is a common surgical option for the treatment of medically refractory Parkinson's disease (PD). Manufacturer and User Facility Device Experience (MAUDE), a United States Food and Drug Administration (FDA)-compiled database of adverse event reports related to medical devices, is a public resource that can provide insight into the relative frequency of complications and patient complaints. MATERIALS AND METHODS: We accessed the MAUDE database and queried for adverse reports for deep brain stimulators implanted for PD from January 1, 2009 to December 31, 2018. Complaints were classified into device malfunction, patient non-compliance, patient complaint, surgically managed complications (i.e. complications that are corrected via surgery), and death. Patient complaints were further stratified into ineffective stimulation, shock, overstimulation, battery-related problems, or pain at the pulse generator site. Surgically managed complications were classified as intraoperative complications, impedance, migration, erosion, infection, lead fracture, and lead disconnection. Each event could receive multiple classifications and subclassifications. RESULTS: A total of 4,189 adverse event reports was obtained. These encompassed 2,805 patient complaints. Within this group, 797 (28%) events were classified as ineffective stimulation. There were 1,382 surgically managed complications, 104 (8%) of which were intraoperative complications, 757 (55%) documented impedance issues, 381 (28%) infections, and 413 (30%) lead-related issues. There were 53 documented deaths. CONCLUSIONS: The MAUDE database has potential use as a real time monitor for elucidating the relative occurrence of complications associated with deep brain stimulation. It also allows for the analysis of device-related complications in specific patient populations. Although the database is useful in this endeavor, it requires improvements particularly in the standardization of reporting adverse events.