Changes of biomechanics induced by Equistasi® in Parkinson's disease: coupling between balance and lower limb joints kinematics.

Changes of biomechanics induced by Equistasi® in Parkinson's disease: coupling between balance and lower limb joints kinematics.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Padua, IT · Author affiliation

Department of Information Engineering, University of Padua, Via Gradenigo 6B, 35131, Padua, Italy.
Location evidence

Vicenza, IT · Author affiliation

Fresco Parkinson Center, Villa Margherita, S. Stefano, Vicenza, Italy.
Location evidence

New York City, US · Author affiliation

The Marlene and Paolo Fresco Institute for Parkinson's and Movement Disorders, Department of Neurology, NYU School of Medicine, New York, NY, USA.
Location evidence

Rome, IT · Author affiliation

Istituto di Ricovero e Cura a Carattere Scientifico, Rome, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Axial disorders, including postural deformities, postural instability, and gait disturbances, are among the most disabling symptoms of Parkinson's disease (PD). Equistasi®, a wearable proprioceptive stabilizer device, has been proposed as neurological rehabilitative device for this set of symptoms. To investigate the effects of the device on gait and balance, 24 participants affected by PD were enrolled in this crossover double-dummy, randomized, controlled study. Subjects were assessed four times before and after 8 weeks treatment with either active or placebo device; one-month wash-out was taken between treatments, in a 20-week timeframe. Gait analysis and instrumented Romberg test were performed with the aid of a sterofotogrammetric system and two force plates. Joint kinematics, spatiotemporal parameters of gait and center of pressure parameters were extracted. Paired T-test (p < 0.05) was adopted after evidence of normality to compare the variables across different acquisition sessions; Wilcoxon was adopted for non-normal distributions. Before and after the treatment with the active device, statistically significant improvements were observed in trunk flexion extension and in the ankle dorsi-plantarflexion. Regarding balance assessment, significant improvements were reported at the frequencies corresponding to vestibular system. These findings may open new possibilities on PD's rehabilitative interventions. Research question, tailored design of the study, experimental acquisition overview, main findings, and conclusions.