RESEARCH / DISCOVERY
← Back to the library

Transition metal dichalcogenides to optimize the performance of peptide-imprinted conductive polymers as electrochemical sensors.

Transition metal dichalcogenides to optimize the performance of peptide-imprinted conductive polymers as electrochemical sensors.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Kaohsiung, TW · Author affiliation

Department of Materials Science and Engineering, I-Shou University, Kaohsiung, 84001, Taiwan.
Location evidence

Albuquerque, US · Author affiliation

Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM, 87131, USA.
Location evidence

MX · Author affiliation · country only

Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM, 87131, USA.
Location evidence

Hsinchu, TW · Author affiliation

Taiwan Semiconductor Research Institute, Hsinchu, 30009, Taiwan.
Location evidence

Luxembourg, LU · Author affiliation

Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, L-4367, Belvaux, Luxembourg.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Molecularly imprinted polymer (MIP)-based electrochemical sensors for the protein α-synuclein (a marker for Parkinson's disease) were developed using a peptide epitope from the protein. MIPs doped with various concentrations and species of transition metal dichalcogenides (TMDs) to enhance conductivity were electropolymerized with and without template molecules. The current during the electropolymerization was compared with that associated with the electrochemical response (at 0.24~0.29 V vs. ref. electrode) to target peptide molecules in the finished sensor. We found that this relationship can aid in the rational design of conductive MIPs for the recognition of biomarkers in biological fluids. The sensing range and limit of detection of TMD-doped imprinted poly(AN-co-MSAN)-coated electrodes were 0.001-100 pg/mL and 0.5 fg/mL (SNR = 3), respectively. To show the potential applicability of the MIP electrochemical sensor, cell culture medium from PD patient-specific midbrain organoids generated from induced pluripotent stem cells was analyzed. α-Synuclein levels were found to be significantly reduced in the organoids from PD patients, compared to those generated from age-matched controls. The relative standard deviation and recovery are less than 5% and 95-115%, respectively. Preparation of TMD-doped α-synuclein (SNCA) peptide-imprinted poly(AN-co-MSAN)-coated electrodes.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE