RESEARCH / DISCOVERY
← Back to the library

Clinical utility of DaTscan in patients with suspected Parkinsonian syndrome: a systematic review and meta-analysis.

Clinical utility of DaTscan in patients with suspected Parkinsonian syndrome: a systematic review and meta-analysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Chicago, US · Author affiliation

Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
Location evidence

Tucson, US · Author affiliation

Departments of Medical Imaging Medicine, and Biomedical Engineering, University of Arizona, Tucson, AZ, USA.
Location evidence

London, GB · Author affiliation

King's Technology Evaluation Centre, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. anchalki@gmail.com.
Location evidence

Marlborough, US · Author affiliation

GE Healthcare, Marlborough, MA, USA.
Location evidence

GB · Author affiliation · country only

GE Healthcare, Pollards Wood, Nightingales Ln, Chalfont Saint Giles, UK.
Location evidence

Padua, IT · Author affiliation

Department of Neuroscience, University of Padua, Padua, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Images of DaTscan (ioflupane [123I] SPECT) have been used as an adjunct to clinical diagnosis to facilitate the differential diagnosis of neurodegenerative (ND) Parkinsonian Syndrome (PS) vs. non-dopamine deficiency aetiologies of Parkinsonism. Despite several systematic reviews having summarised the evidence on diagnostic accuracy, the impact of imaging results on clinical utility has not been systematically assessed. Our objective was to examine the available evidence on the clinical utility of DaTscan imaging in changing diagnosis and subsequent management of patients with suspected PS. We performed a systematic review of published studies of clinical utility from 2000 to 2019 without language restrictions. A meta-analysis of change in diagnosis and management rates reported from each study was performed using a random-effects model and logit transformation. Sub-group analysis, meta-regression and sensitivity analysis was performed to explore heterogeneity. Twenty studies met the inclusion criteria. Thirteen of these contributed to the meta-analyses including 950 and 779 patients with a reported change in management and change in diagnosis, respectively. The use of DaTscan imaging resulted in a change in management in 54% (95% CI: 47-61%) of patients. Change in diagnosis occurred in 31% (95% CI: 22-42%) of patients. The two pooled analyses were characterised by high levels of heterogeneity. Our systematic review and meta-analysis show that imaging with DaTscan was associated with a change in management in approximately half the patients tested and the diagnosis was modified in one third. Regardless of time from symptom onset to scan results, these changes were consistent. Further research focusing on specific patient subgroups could provide additional evidence on the impact on clinical outcomes.