RESEARCH / DISCOVERY
← Back to the library

Safety and Tolerability of Burst-Cycling Deep Brain Stimulation for Freezing of Gait in Parkinson's Disease.

Safety and Tolerability of Burst-Cycling Deep Brain Stimulation for Freezing of Gait in Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Norman, US · Author affiliation

Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, United States.
Location evidence

Loveland, US · Author affiliation

Banner Health Physicians Colorado, Loveland, CO, United States.
Location evidence

US · Author affiliation · country only

Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States.
Location evidence

Minneapolis, US · Author affiliation

Restorative Therapies Group Implantables, Research and Core Technology, Medtronic, Minneapolis, MN, United States.
Location evidence

Nagoya, JP · Author affiliation

Department of Neurology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Background: Freezing of gait (FOG) is a common symptom in Parkinson's disease (PD) and can be difficult to treat with dopaminergic medications or with deep brain stimulation (DBS). Novel stimulation paradigms have been proposed to address suboptimal responses to conventional DBS programming methods. Burst-cycling deep brain stimulation (BCDBS) delivers current in various frequencies of bursts (e.g., 4, 10, or 15 Hz), while maintaining an intra-burst frequency identical to conventional DBS. Objective: To evaluate the safety and tolerability of BCDBS in PD patients with FOG. Methods: Ten PD subjects with STN or GPi DBS and complaints of FOG were recruited for this single center, single blinded within-subject crossover study. For each subject, we compared 4, 10, and 15 Hz BCDBS to conventional DBS during the PD medication-OFF state. Results: There were no serious adverse events with BCDBS. It was feasible and straightforward to program BCDBS in the clinic setting. The benefit was comparable to conventional DBS in measures of FOG, functional mobility and in PD motor symptoms. BCDBS had lower battery consumption when compared to conventional DBS. Conclusions: BCDBS was feasible, safe and well tolerated and it has potential to be a viable future DBS programming strategy.