RESEARCH / DISCOVERY
← Back to the library

Dyskinesia estimation during activities of daily living using wearable motion sensors and deep recurrent networks.

Dyskinesia estimation during activities of daily living using wearable motion sensors and deep recurrent networks.

Read the original publication

Where did the research take place?

Possible study sites were matched from the text; these need review.

Along, IN · Possible study site

We used movement data collected from the upper and lower extremities of 15 PwPs along with a deep recurrent model to estimate dyskinesia severity as they perform different activities of daily living (ADL).
Location evidence

Boca Raton, US · Author affiliation

Department of Computer and Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL, 33431, USA.
Location evidence

New York City, US · Author affiliation

Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Location evidence

US · Author affiliation · country only

Department of Neurology, University of Rochester Medical Center, Rochester, NY, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Levodopa-induced dyskinesias are abnormal involuntary movements experienced by the majority of persons with Parkinson's disease (PwP) at some point over the course of the disease. Choreiform as the most common phenomenology of levodopa-induced dyskinesias can be managed by adjusting the dose/frequency of PD medication(s) based on a PwP's motor fluctuations over a typical day. We developed a sensor-based assessment system to provide such information. We used movement data collected from the upper and lower extremities of 15 PwPs along with a deep recurrent model to estimate dyskinesia severity as they perform different activities of daily living (ADL). Subjects performed a variety of ADLs during a 4-h period while their dyskinesia severity was rated by the movement disorder experts. The estimated dyskinesia severity scores from our model correlated highly with the expert-rated scores (r = 0.87 (p < 0.001)), which was higher than the performance of linear regression that is commonly used for dyskinesia estimation (r = 0.81 (p < 0.001)). Our model provided consistent performance at different ADLs with minimum r = 0.70 (during walking) to maximum r = 0.84 (drinking) in comparison to linear regression with r = 0.00 (walking) to r = 0.76 (cutting food). These findings suggest that when our model is applied to at-home sensor data, it can provide an accurate picture of changes of dyskinesia severity facilitating effective medication adjustments.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE