RESEARCH / DISCOVERY
← Back to the library

Determination of the Antioxidant Activity of Samples of Tea and Commercial Sources of Vitamin C, Using an Enzymatic Biosensor.

Determination of the Antioxidant Activity of Samples of Tea and Commercial Sources of Vitamin C, Using an Enzymatic Biosensor.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

BR · Author affiliation · country only

Pesticide Residue Analysis Center, Federal University of Maranhão, UFMA. Av. Portugueses, CCET, Bacanga, CEP, São Luis, MA 65080-040, Brazil.
Location evidence

Braşov, RO · Author affiliation

Center for Fundamental Research and Prevention Strategies in Medicine, Department of Fundamental, Prophylactic and Clinical Specialties, Transilvania University of Brasov, 500039 Brasov, Romania.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Antioxidants are synthetic or natural compounds capable of preventing or delaying oxidative damage caused by chemical species that can oxidize cell biomolecules, such as proteins, membranes, and DNA, leading to the development of various pathologies, such as cancer, atherosclerosis, Parkinson, Alzheimer, and other diseases serious. In this study, an amperometric biosensor was used to determine the antioxidant activity of teas and effervescent products based on vitamin C, available on the market. A sensor composed of three electrodes was used. The performance of the following electrochemical mediators was evaluated: meldola blue combined with Reineck salt (MBRS), Prussian blue (PB), and cobalt phthalocyanine (CoPC), as well as the time of polymerization in the enzymatic immobilization process and the agitation process during chronoamperometric measurements. Prussian blue proved to be more efficient as a mediator for the desired purposes. After optimizing the construction stages of the biosensor, as well as the operational parameters, it presented stability for a period of 7 months. The results clearly indicate that the biosensor can be successfully used to detect fraud in products called "antioxidants" or even in drugs containing less ascorbic acid than indicated on the labels. The detection limit was set at 4.93 µmol·L-1.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE