RESEARCH / DISCOVERY
← Back to the library

Comparison of clinical outcomes and accuracy of electrode placement between robot-assisted and conventional deep brain stimulation of the subthalamic nucleus: a single-center study.

Comparison of clinical outcomes and accuracy of electrode placement between robot-assisted and conventional deep brain stimulation of the subthalamic nucleus: a single-center study.

Read the original publication

Where did the research take place?

Possible study sites were matched from the text; these need review.

Lyon, FR · Possible study site

METHODS: In this single-center open-label study, we prospectively collected data from 48 consecutive PD patients who underwent RAS (Neuromate®; n = 20) or FSS (n = 28) STN DBS with the same MRI-based STN targeting between October 2016 and December 2018 in the university neurological hospital of Lyon, France.
Location evidence

Lyon, FR · Author affiliation

Service de Neurologie C, Centre Expert Parkinson, Hôpital Neurologique et Neurochirurgical Pierre Wertheimer, Hospices Civils de Lyon, 69003, Lyon, France.
Location evidence

Saint-Genis-Laval, FR · Author affiliation

Service de Médecine Physique et de Réadaptation, Hôpital Henry Gabrielle, Hospices Civils de Lyon, 69230, Saint-Genis-Laval, France.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Several surgical methods are used for deep brain stimulation (DBS) of the subthalamic nucleus (STN) in Parkinson's disease (PD). This study aimed to compare clinical outcomes and electrode placement accuracy after robot-assisted (RAS) versus frame-based stereotactic (FSS) STN DBS in Parkinson's disease. METHODS: In this single-center open-label study, we prospectively collected data from 48 consecutive PD patients who underwent RAS (Neuromate®; n = 20) or FSS (n = 28) STN DBS with the same MRI-based STN targeting between October 2016 and December 2018 in the university neurological hospital of Lyon, France. Clinical variables were assessed before and 1 year after surgery. The number of electrode contacts within the STN was determined by merging post-operative CT and pre-operative MRI using Brainlab® GUIDE™XT software. RESULTS: One year after surgery, the improvement of motor manifestations (p = 0.18), motor complications (p = 0.80), and quality of life (p= 0.30) and the reduction of dopaminergic treatment (p = 0.94) and the rate of complications (p = 0.99) were similar in the two groups. Surgery duration was longer in the RAS group (p = 0.0001). There was no difference in the number of electrode contacts within the STN. CONCLUSION: This study demonstrates that RAS and FSS STN DBS for PD provide similar clinical outcomes and accuracy of electrode placement.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE