RESEARCH / DISCOVERY
← Back to the library

Closed-loop programming using external responses for deep brain stimulation in Parkinson's disease.

Closed-loop programming using external responses for deep brain stimulation in Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Tokyo, JP · Author affiliation

Department of Neurology, Juntendo University School of Medicine, Tokyo, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Deep brain stimulation (DBS) is an established treatment for Parkinson's disease (PD). Clinicians face various challenges in adjusting stimulation parameters and configurations in clinical DBS settings owing to inexperience, time constraints, and recent advances in DBS technology that have expanded the number of possible contact configurations. We aimed to assess the efficacy of a closed-loop algorithm (CLA) for the DBS-programming method using external motion sensor-based motor assessments in patients with PD. METHODS: In this randomized, double-blind, crossover study, we enrolled 12 patients who underwent eight-ring-contact DBS lead implantations bilaterally in the subthalamic nucleus. The DBS settings of the participants were programmed using a standard of care (SOC) and CLA method. The clinical effects of both programming methods were assessed in a randomized crossover fashion. The outcomes were evaluated using the Unified Parkinson's Disease Scale part III (UPDRS-III) and sensor-based scores for baseline (medication-off/stimulation-off) and both programming methods. The number of programming steps required for each programming method was also recorded. RESULTS: The UPDRS-III scores and sensor-based scores were significantly improved by SOC and CLA settings compared to the baseline. No statistical difference was observed between SOC and CLA. The programming steps were significantly reduced in the CLA settings compared to those in the SOC. No serious adverse events were observed. CONCLUSION: CLA can optimize DBS settings prospectively with similar therapeutic benefits as that of the SOC and reduce the number of programming steps. Automated optimization of DBS settings would reduce the burden of programming for both clinicians and patients.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE