The Impact of Reducing the Number of Wearable Devices on Measuring Gait in Parkinson Disease: Noninterventional Exploratory Study.
The Impact of Reducing the Number of Wearable Devices on Measuring Gait in Parkinson Disease: Noninterventional Exploratory Study.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Cambridge, US · Author affiliation
Digital Medicine & Translational Imaging, Early Clinical Development, Pfizer Inc, Cambridge, MA, United States.Location evidence
Boston, US · Author affiliation
Tufts Medical Center, Boston, MA, United States.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Measuring free-living gait using wearable devices may offer higher granularity and temporal resolution than the current clinical assessments for patients with Parkinson disease (PD). However, increasing the number of devices worn on the body adds to the patient burden and impacts the compliance. OBJECTIVE: This study aimed to investigate the impact of reducing the number of wearable devices on the ability to assess gait impairments in patients with PD. METHODS: A total of 35 volunteers with PD and 60 healthy volunteers performed a gait task during 2 clinic visits. Participants with PD were assessed in the On and Off medication state using the Movement Disorder Society version of the Unified Parkinson Disease Rating Scale (MDS-UPDRS). Gait features derived from a single lumbar-mounted accelerometer were compared with those derived using 3 and 6 wearable devices for both participants with PD and healthy participants. RESULTS: A comparable performance was observed for predicting the MDS-UPDRS gait score using longitudinal mixed-effects model fit with gait features derived from a single (root mean square error [RMSE]=0.64; R2=0.53), 3 (RMSE=0.64; R2=0.54), and 6 devices (RMSE=0.54; R2=0.65). In addition, MDS-UPDRS gait scores predicted using all 3 models differed significantly between On and Off motor states (single device, P=.004; 3 devices, P=.004; 6 devices, P=.045). CONCLUSIONS: We observed a marginal benefit in using multiple devices for assessing gait impairments in patients with PD when compared with gait features derived using a single lumbar-mounted accelerometer. The wearability burden associated with the use of multiple devices may offset gains in accuracy for monitoring gait under free-living conditions.