RESEARCH / DISCOVERY
← Back to the library

Intraoperative Neurophysiologic Assessment in Deep Brain Stimulation Surgery and its Impact on Lead Placement.

Intraoperative Neurophysiologic Assessment in Deep Brain Stimulation Surgery and its Impact on Lead Placement.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Munich, DE · Author affiliation

Department of Neurosurgery, Klinikum rechts der Isar, Technical University of Munich, Germany.
Location evidence

Zürich, CH · Author affiliation

Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVES: While the efficacy of deep brain stimulation (DBS) to treat various neurological disorders is undisputed, the surgical methods differ widely and the importance of intraoperative microelectrode recording (MER) or macrostimulation (MS) remains controversially debated. The objective of this study is to evaluate the impact of MER and MS on intraoperative lead placement. PATIENTS AND METHODS: We included 101 patients who underwent awake bilateral implantation of electrodes in the subthalamic nucleus with MER and MS for Parkinson's disease from 2009 to 2017 in a retrospective observational study. We analyzed intraoperative motor outcomes between anatomically planned stimulation point (PSP) and definite stimulation point (DSP), lead adjustments and Unified Parkinson's Disease Rating Scale Item III (UPDRS-III), levodopa equivalent daily dose (LEDD), and adverse events (AE) after 6 months. RESULTS: We adjusted 65/202 leads in 47/101 patients. In adjusted leads, MS results improved significantly when comparing PSP and DSP (p < 0.001), resulting in a number needed to treat of 9.6. After DBS, UPDRS-III and LEDD improved significantly after 6 months in adjusted and nonadjusted patients (p < 0.001). In 87% of leads, the active contact at 6 months still covered the optimal stimulation point during surgery. In total, 15 AE occurred. CONCLUSION: MER and MS have a relevant impact on the intraoperative decision of final lead placement and prevent from a substantial rate of poor stimulation outcome. The optimal stimulation points during surgery and chronic stimulation strongly overlap. Follow-up UPDRS-III results, LEDD reductions, and DBS-related AE correspond well to previously published data.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE