RESEARCH / DISCOVERY
← Back to the library

Effect of pulmonary vein isolation on atrial fibrillation recurrence after accessory pathway ablation in patients with Wolff-Parkinson-White syndrome.

Effect of pulmonary vein isolation on atrial fibrillation recurrence after accessory pathway ablation in patients with Wolff-Parkinson-White syndrome.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Zhengzhou, CN · Author affiliation

Heart Centre of Henan Provincial People's Hospital, Central China Fuwai Hospital, Central China Fuwai Hospital of Zhengzhou University, Zhengzhou, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Although successful ablation of the accessory pathway (AP) eliminates atrial fibrillation (AF) in some of patients with Wolff-Parkinson-White (WPW) syndrome and paroxysmal AF, in other patients it can recur. HYPOTHESIS: Whether adding pulmonary vein isolation (PVI) after successful AP ablation effectively prevents AF recurrence in patients with WPW syndrome is unknown. METHODS: We retrospectively studied 160 patients (102 men, 58 women; mean age, 46 ± 14 years) with WPW syndrome and paroxysmal AF who underwent AP ablation, namely 103 (64.4%) undergoing only AP ablation (AP group) and 57 (35.6%) undergoing AP ablation plus PVI (AP + PVI group). Advanced interatrial block (IAB) was defined as a P-wave duration of >120 ms and biphasic (±) morphology in the inferior leads, using 12-lead electrocardiography (ECG). RESULTS: During the mean follow-up period of 30.9 ± 9.2 months (range, 3-36 months), 22 patients (13.8%) developed AF recurrence. The recurrence rate did not differ in patients in the AP + PVI group and AP group (15.5% vs 10.5%, respectively; P = .373). Univariable and multivariable Cox regression analyses showed that PVI was not associated with the risk of AF recurrence (hazard ratio, 0.66; 95% confidence interval, 0.26-1.68; P = .380). In WPW patients with advanced IAB, the recurrence rate was lower in patients in the AP + PVI group vs the AP group (90% vs 33.3%, respectively; P = .032). CONCLUSIONS: PVI after successful AP ablation significantly reduced the AF recurrence rate in WPW patients with advanced IAB. Screening of a resting 12-lead ECG immediately after AP ablation helps identify patients in whom PVI is beneficial.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE