RESEARCH / DISCOVERY
← Back to the library

Preoperative Magnetic Resonance Image Quality in Motion Disorder Patients Scheduled for Deep Brain Stimulation Surgery.

Preoperative Magnetic Resonance Image Quality in Motion Disorder Patients Scheduled for Deep Brain Stimulation Surgery.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Helsinki, FI · Author affiliation

Department of Anesthesia, Intensive Care and Pain Medicine, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
Location evidence

Amsterdam, NL · Author affiliation

Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: To obtain magnetic resonance (MR) images of good quality for accurate target localization in deep brain stimulation (DBS) surgery, sedation or anesthesia may be used, although their usefulness has not been proven. OBJECTIVE: To assess whether sedation or general anesthesia (GA) improve the quality of MR imaging (MRI). METHODS: The records of DBS procedures for Parkinson's disease (PD), dystonia, and essential tremor in our tertiary neurosurgical unit between January 2011 and June 2016 were reviewed. Adult patients with preoperative MR images were included. Patient records concerning MRI, surgery, adverse events, and clinical outcome were retrospectively scrutinized and analyzed. MR image quality was assessed by two independent radiologists. RESULTS: A total of 215 preoperative MR images for 177 DBS procedures were analyzed. The MRI sequences performed under GA were superior to those performed without anesthesia or under sedation (p < 0.01). Virtually all images captured under GA were of good quality, while the proportions among those captured with sedation or without anesthesia were <65%. Good image quality was not associated with better clinical outcome (>50% improvement in the Unified Parkinson's Disease Rating Scale III score) among patients with PD. CONCLUSION: GA was associated with better MRI sequences than intravenous sedation or no anesthesia.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE