RESEARCH / DISCOVERY
← Back to the library

Reliability and Validity of Pupillary Response During Dual-Task Balance in Parkinson Disease.

Reliability and Validity of Pupillary Response During Dual-Task Balance in Parkinson Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: To investigate the reliability and validity of pupillary response during dual-task balance conditions in individuals with Parkinson disease (PD). DESIGN: Cross-sectional study. SETTING: University of Kansas Medical Center Parkinson's Disease and Movement Disorder Center. PARTICIPANTS: Participants (N=68) included individuals with PD (n=33) and healthy controls (n=35). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Pupillary response was the main outcome measure that was measured during the following conditions: single-task balance eyes open, single-task balance eyes occluded, dual-task eyes open, and dual-task eyes occluded. After each condition, the National Aeronautics and Space Administration-Task Load Index (NASA-TLX) was administered to assess self-reported cognitive workload. To examine the test-retest reliability of the pupillary response, the conditions were administered twice for each individual within 2 hours. Intraclass correlation coefficients (ICC) were used to analyze the test-retest reliability of pupillary response in each condition for both groups. Pearson's r correlation was used to assess the convergent validity of pupillary response against the NASA-TLX. RESULTS: The test-retest reliability was excellent for both groups in almost all conditions (ICC>0.75). There were no correlations between pupillary response and the NASA-TLX. However, increased mental demand (a subitem of the NASA-TLX) significantly correlated with increased pupillary response in individuals with PD (r=0.38; P=.03). CONCLUSIONS: Pupillary response showed excellent test-retest reliability and validity during dual-task balance for individuals with PD and healthy controls. Overall, these results suggest that pupillary response represents a stable index of cognitive workload during dual-task balance in individuals with PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE