RESEARCH / DISCOVERY
← Back to the library

Diagnostic Value of the Early Heart-to-Mediastinum Count Ratio in Cardiac 123I-mIBG Imaging for Parkinson's Disease.

Diagnostic Value of the Early Heart-to-Mediastinum Count Ratio in Cardiac 123I-mIBG Imaging for Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Rome, IT · Author affiliation

Department of Molecular Medicine, Sapienza, "Sapienza" University of Rome, viale Regina Elena,324, 00161Rome, Italy.
Location evidence

Bari, IT · Author affiliation

Nuclear Medicine Unit, Interdisciplinary Department of Medicine - University of Bari "Aldo Moro", Bari, Italy.
Location evidence

IT · Author affiliation · country only

Department of Medical Physics, Azienda Ospedaliera Universitaria Policlinico Umberto I, viale del Policlinico 155, 00161Rome, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Early diagnosis of Parkinson's disease (PD) is of primary importance. The delayed (3-4 h after injection) Iodine-123-Metaiodobenzylguanidine (123I-mIBG) scintigraphy has been proven to be effective in early differential diagnosis for Lewy body disease. But early imaging (15-30 min after injection) has only been marginally studied for its possible diagnostic role. In this prospective study, a threshold for the early Heart-to-Mediastinum (H/M) count ratio has been investigated, obtaining a diagnostic accuracy analogous to conventional, delayed imaging. METHODS: One hundred and eight patients with suspected Parkinson's disease (PD) were acquired after 15 and 240 minutes from the injection of 150-185 MBq of 123I-mIBG. The early and late H/M (He/Me and Hl/Ml) were evaluated by drawing Region-of-Interests on the heart and the upper half of the mediastinum. Optimal threshold (Youden index) and overall predictive performance were determined by receiver operating characteristic curve, classifying tentatively patients having an Hl/Ml lower than 1.6 as suffering from PD. RESULTS: He/Me was not significantly different from Hl/Ml (p-value=0.835). The Area-under-curve was 0.935 (95%CI: 0.845-1.000). The He/Me optimal threshold was 1.66, with sensitivity, specificity, and diagnostic accuracy of 95.5%, 85.7 and 90.7% respectively. CONCLUSION: The He/Me Ratio is almost as accurate as the widely used delayed 123I-mIBG imaging, reducing the burden of delayed imaging but preserving the diagnostic accuracy of the method. Moreover the differential diagnosis in Parkinson's disease can be made in just 25 minutes against the 4 hours currently needed, lowering costs of the healthcare system and improving patients compliance.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE