RESEARCH / DISCOVERY
← Back to the library

Short-echo-time magnitude image derived from quantitative susceptibility mapping could resemble neuromelanin-sensitive MRI image in substantia nigra.

Short-echo-time magnitude image derived from quantitative susceptibility mapping could resemble neuromelanin-sensitive MRI image in substantia nigra.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Huashan, CN · Author affiliation

Department of Radiology, Huashan Hospital, Fudan University, Shanghai, 200040, China.
Location evidence

Shanghai, CN · Author affiliation

Department of Radiology, Huashan Hospital, Fudan University, Shanghai, 200040, China.
Location evidence

Beijing, CN · Author affiliation

GE Healthcare China, Beijing, 100176, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: In this study, we explored whether the proposed short-echo-time magnitude (setMag) image derived from quantitative susceptibility mapping (QSM) could resemble NM-MRI image in substantia nigra (SN), by quantitatively comparing the spatial similarity and diagnosis performances for Parkinson's disease (PD). METHODS: QSM and NM-MRI were performed in 18 PD patients and 15 healthy controls (HCs). The setMag images were calculated using the short-echo-time magnitude images. Bilateral hyperintensity areas of SN (SNhyper) were manually segmented on setMag and NM-MRI images by two raters in a blinded manner. The inter-rater reliability was evaluated by the intraclass correlation coefficients (ICC) and the Dice similarity coefficient (DSC). Then the inter-modality (i.e. setMag and NM-MRI) spatial similarity was quantitatively assessed using DSC and volume of the consensual voxels identified by both of two raters. The performances of mean SNhyper volume for PD diagnosis on setMag and NM-MRI images were evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The SNhyper segmented by two raters showed substantial to excellent inter-rater reliability for both setMag and NM-MRI images. The DSCs of SNhyper between setMag and NM-MRI images showed substantial to excellent voxel-wise overlap in HCs (0.80 ~ 0.83) and PD (0.73 ~ 0.76), and no significant difference was found between the SNhyper volumes of setMag and NM-MRI images in either HCs or PD (p > 0.05). The mean SNhyper volume was significantly decreased in PD patients in comparison with HCs on both setMag images (77.61 mm3 vs 95.99 mm3, p < 0.0001) and NM-MRI images (79.06 mm3 vs 96.00 mm3, p < 0.0001). Areas under the curve (AUCs) of mean SNhyper volume for PD diagnosis were 0.904 on setMag and 0.906 on NM-MRI images. No significant difference was found between the two curves (p = 0.96). CONCLUSIONS: SNhyper on setMag derived from QSM demonstrated substantial spatial overlap with that on NM-MRI and provided comparable PD diagnostic performance, providing a new QSM-based multi-contrast imaging strategy for future PD studies.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE