RESEARCH / DISCOVERY
← Back to the library

Carbon dots for lysosome targeting and imaging of lysosomal pH and Cys/Hcy in living cells.

Carbon dots for lysosome targeting and imaging of lysosomal pH and Cys/Hcy in living cells.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Taiyuan, CN · Author affiliation

Department of Chemistry, Taiyuan Normal University, 319 University Street, Yuci District, Jinzhong 030619, P. R. China. liuqiaoling@tynu.edu.cn lilin@tynu.edu.cn.
Location evidence

Yuci, CN · Author affiliation

Department of Chemistry, Taiyuan Normal University, 319 University Street, Yuci District, Jinzhong 030619, P. R. China. liuqiaoling@tynu.edu.cn lilin@tynu.edu.cn.
Location evidence

Jinzhong, CN · Author affiliation

Department of Chemistry, Taiyuan Normal University, 319 University Street, Yuci District, Jinzhong 030619, P. R. China. liuqiaoling@tynu.edu.cn lilin@tynu.edu.cn.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The abnormal concentrations of both biothiols and pH in lysosomes are seriously related to many major diseases, such as Parkinson's and Alzheimer's diseases. Up to now, there are few reports that clearly illustrate the relationship between lysosomal pH and biothiols via fluorescence assay. Herein, novel carbon dots (Scy-CDs) are prepared with good water dispersibility and excellent photostability, and a large Stokes shift of 106 nm is exhibited under an excitation wavelength of 450 nm. The remarkable pH-dependent behavior of Scy-CDs is presented with the fluorescence quenching based on the donor-excited photoinduced electron transfer (d-PET) process. The pKa value is 5.30, which is in good agreement with the range of the normal and abnormal lysosomal pH. Upon the addition of cysteine (Cys) or homocysteine (Hcy), the d-PET process is effectively inhibited with fluorescence recovery totally. The significant co-localization of Scy-CDs with Lyso-Tracker Deep Red in HEp-2 cells and the Pearson correlation coefficient 0.88 strongly suggest that the Scy-CDs can target lysosomal pH and Cys/Hcy in living cells.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE