RESEARCH / DISCOVERY
← Back to the library

Detection of caffeine and its main metabolites for early diagnosis of Parkinson's disease using micellar electrokinetic capillary chromatography.

Detection of caffeine and its main metabolites for early diagnosis of Parkinson's disease using micellar electrokinetic capillary chromatography.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Shijiazhuang, CN · Author affiliation

Key Laboratory of Environment and Human Health, School of Public Health, Hebei Medical University, Shijiazhuang, P. R. China.
Location evidence

Los Angeles, US · Author affiliation

School of Dentistry and Jonsson Comprehensive Cancer Center, University of California, Los Angeles, California, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Caffeine (CA) is a common xanthine alkaloid found in tea leaves, coffee beans, and other natural plants, and is the most widely used psychotropic substance in the world. Accumulating evidence suggests that low plasma levels of CA and its metabolites may serve as reliable diagnostic markers for early Parkinson's disease (PD) patients. In this study, we demonstrated a new MEKC method for determining CA and its three main downstream metabolites, paraxanthine (PX), theobromine (TB), and theophylline (TP), in human plasma. Plasma samples were collected, and analyzed using MEKC, after SPE. The running buffer was composed of 35 mM phosphate, pH of 10.5, and 25 mM SDS. The separation voltage was 15 kV and the detection wavelength was at 210 nm. Under the optimum conditions, four distinct analytes were completely separated and detected in less than 12 min. Method limits of detection were as low as 7.5 ng/mL for CA, 5.0 ng/mL for TB, and 4.0 ng/mL for both PX and TP. The recoveries were between 88.0% and 105.9%. This method was successfully applied to 27 human plasma samples. The results indicate that the plasma concentrations of the four analytes are significantly lower in patients with early PD than in control subjects (p < 0.05). The area under curve was improved to 0.839 when CA and its three main metabolites were included, suggesting that MEKC testing of CA, TP, TB, and PX may serve as a potential method for early diagnosis of PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE