Factors Influencing Electrode Position and Bending of the Proximal Lead in Deep Brain Stimulation for Movement Disorders.

Factors Influencing Electrode Position and Bending of the Proximal Lead in Deep Brain Stimulation for Movement Disorders.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Minneapolis, US · Author affiliation

Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: The introduction of intracranial air (ICA) during deep brain stimulation (DBS) surgery is thought to have a negative influence on targeting and clinical outcomes. OBJECTIVE: To investigate ICA volumes following surgery and other patient-specific factors as potential variables influencing translocation of the DBS electrode and proximal lead bowing. METHODS: High-resolution postoperative computed tomography scans (≤1.0 mm resolution in all directions) within 24 h following DBS surgery and 4-6 weeks of follow-up were acquired. A total of 50 DBS leads in 33 patients were available for analysis. DBS leads included Abbott/St. Jude Medical InfinityTM, Boston Scientific VerciseTM, and Medtronic 3389TM. RESULTS: Both ICA volume and anatomical target were significantly associated with measures of DBS electrode translocation. ICA volume and DBS lead model were found to be significant predictors of proximal lead bowing. Measures of proximal lead bowing and translocation along the electrode trajectory for the Medtronic 3389TM DBS lead were significantly larger than measures for the Abbott/St. Jude Medical InfinityTM and Boston Scientific VerciseTM DBS leads. CONCLUSION: The association between ICA volume and translocation of the DBS electrode is small in magnitude and not clinically relevant for DBS cases within a normal range of postoperative subdural air volumes. Differences in proximal lead bowing observed between DBS leads may reflect hardware engineering subtleties in the construction of DBS lead models.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE