RESEARCH / DISCOVERY
← Back to the library

A Wearable System to Objectify Assessment of Motor Tasks for Supporting Parkinson's Disease Diagnosis.

A Wearable System to Objectify Assessment of Motor Tasks for Supporting Parkinson's Disease Diagnosis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Pontedera, IT · Author affiliation

The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio 34, Pontedera, 56025 Pisa, Italy.
Location evidence

Pisa, IT · Author affiliation

The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio 34, Pontedera, 56025 Pisa, Italy.
Location evidence

Massa, IT · Author affiliation

O.U. Neurology, Ospedale delle Apuane, AUSL Toscana Nord Ovest, via Enrico Mattei, 21, 54100 Massa, Italy.
Location evidence

Florence, IT · Author affiliation

Department of Industrial Engineering, University of Florence, via Santa Marta 3, 50139 Florence, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Objective assessment of the motor evaluation test for Parkinson's disease (PD) diagnosis is an open issue both for clinical and technical experts since it could improve current clinical practice with benefits both for patients and healthcare systems. In this work, a wearable system composed of four inertial devices (two SensHand and two SensFoot), and related processing algorithms for extracting parameters from limbs motion was tested on 40 healthy subjects and 40 PD patients. Seventy-eight and 96 kinematic parameters were measured from lower and upper limbs, respectively. Statistical and correlation analysis allowed to define four datasets that were used to train and test five supervised learning classifiers. Excellent discrimination between the two groups was obtained with all the classifiers (average accuracy ranging from 0.936 to 0.960) and all the datasets (average accuracy ranging from 0.953 to 0.966), over three conditions that included parameters derived from lower, upper or all limbs. The best performances (accuracy = 1.00) were obtained when classifying all the limbs with linear support vector machine (SVM) or gaussian SVM. Even if further studies should be done, the current results are strongly promising to improve this system as a support tool for clinicians in objectifying PD diagnosis and monitoring.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE