Recommendations for Deep Brain Stimulation Device Management During a Pandemic.
Recommendations for Deep Brain Stimulation Device Management During a Pandemic.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Atlanta, US · Author affiliation
Department of Neurology, Emory University, Atlanta, GA, USA.Location evidence
San Francisco, US · Author affiliation
Department of Neurology, Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA.Location evidence
Norman, US · Author affiliation
Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gaineseville, FL, USA.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Most medical centers are postponing elective procedures and deferring non-urgent clinic visits to conserve hospital resources and prevent spread of COVID-19. The pandemic crisis presents some unique challenges for patients currently being treated with deep brain stimulation (DBS). Movement disorder (Parkinson's disease, essential tremor, dystonia), neuropsychiatric disorder (obsessive compulsive disorder, Tourette syndrome, depression), and epilepsy patients can develop varying degrees of symptom worsening from interruption of therapy due to neurostimulator battery reaching end of life, device malfunction or infection. Urgent intervention to maintain or restore stimulation may be required for patients with Parkinson's disease who can develop a rare but potentially life-threatening complication known as DBS-withdrawal syndrome. Similarly, patients with generalized dystonia can develop status dystonicus, patients with obsessive compulsive disorder can become suicidal, and epilepsy patients can experience potentially life-threatening worsening of seizures as a result of therapy cessation. DBS system infection can require urgent, and rarely emergent surgery. Elective interventions including new implantations and initial programming should be postponed. For patients with existing DBS systems, the battery status and electrical integrity interrogation can now be performed using patient programmers, and employed through telemedicine visits or by phone consultations. The decision for replacement of the implantable pulse generator to prevent interruption of DBS therapy should be made on a case-by-case basis taking into consideration battery status and a patient's tolerance to potential therapy disruption. Scheduling of the procedures, however, depends heavily on the hospital system regulations and on triage procedures with respect to safety and resource utilization during the health crisis.