RESEARCH / DISCOVERY
← Back to the library

Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias (COBRA-PATH): a randomized controlled trial.

Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias (COBRA-PATH): a randomized controlled trial.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Rotterdam, NL · Author affiliation

Thoraxcenter, Department of Clinical Electrophysiology, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000, CA, Rotterdam, The Netherlands.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Multiple studies have demonstrated the importance of adequate catheter-tissue contact in the creation of effective lesions during radiofrequency catheter ablation. The development of contact force (CF)-sensing catheters has contributed significantly to improve clinical outcomes in atrial fibrillation. However, CF-sensing technology is not used in the ablation of paroxysmal supraventricular tachycardia (PSVT). The possible reason for this is that PSVT ablation with the conventional approach (i.e. nonirrigated, non-CF-sensing catheters) is considered a relatively low-risk procedure with fairly high success rates (short and long term). The aim of this study is to determine whether CF sensing can further improve the outcomes of PSVT ablation. METHODS/DESIGN: The COBRA-PATH study is a single-center, two-armed, randomized controlled trial. Patients without structural heart disease being referred for electrophysiology study, because of PSVT and potential treatment with radiofrequency (RF) catheter ablation, will be randomly assigned to either manual ablation with standard nonirrigated ablation catheters or manual ablation with an open-irrigated ablation catheter equipped with CF sensing (used in a virtual nonirrigated modus). The primary study endpoint is the difference in the number of RF applications during the ablation of atrioventricular nodal re-entry tachycardia, and that of Wolff-Parkinson-White syndrome and atrioventricular re-entrant tachycardia. Secondary outcome parameters include acute and long-term procedural success rates, overall duration of RF applications, procedure/fluoroscopy durations and safety parameters. DISCUSSION: We expect to see a reduced number/duration of RF applications required to achieve effective lesion creation, and consequently a decrease in total procedure/fluoroscopy times. Although a significant improvement in procedural success rates (acute/long term) might not be feasible to demonstrate (given the relatively high success rate of the standard ablation method), the possible decrease in procedure duration and the consequential reduction of radiation exposure has important clinical implications for both operators and patients undergoing the procedure. TRIAL REGISTRATION: ClinicalTrials, NCT04078685. Retrospectively registered on 2 September 2019.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE