RESEARCH / DISCOVERY
← Back to the library

A rapid, simple and highly sensitive UPLC-MS/MS method for quantitation of pimavanserin in plasma and tissues: Application to pharmacokinetics and brain uptake studies in mice.

A rapid, simple and highly sensitive UPLC-MS/MS method for quantitation of pimavanserin in plasma and tissues: Application to pharmacokinetics and brain uptake studies in mice.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Riyadh, SA · Author affiliation

Department of Pharmaceutical Chemistry and Drug Bioavailability Laboratory, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia; National Organization for Drug Control and Research, Cairo, Egypt. Electronic address: esali@ksu.edu.sa.
Location evidence

Cairo, EG · Author affiliation

Department of Pharmaceutical Chemistry and Drug Bioavailability Laboratory, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia; National Organization for Drug Control and Research, Cairo, Egypt. Electronic address: esali@ksu.edu.sa.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Pimavanserin is a new drug approved by the FDA for Parkinson's disease psychosis and other neurological disorders such as Alzheimer's disease. In this study, we developed a UPLC-MS/MS method to quantify pimavanserin disposition in the brain and its pharmacokinetics in mice. Vilazodone was used as the internal standard. Pimavanserin and IS were extracted by liquid-liquid extraction using tert-butyl methyl ether and separated using an Acquity UPLC BEH™ C18 column. The mobile phase consisted of solvent A (0.1% formic acid in acetonitrile) and B (0.1% formic acid in 20 mM ammonium acetate buffer) (A: B, 70:30 v/v) at a flow rate of 0.25 ml/min. The multiple reaction monitoring transitions were performed at m/z 428.23 → 98.15 for pimavanserin and m/z 441.70 > 155.03 for the IS. The developed method was found to be sensitive, fast, and reproducible. The linearity of the method was ˃0.99 over the range of 0.1-300 ng/mL in plasma and 0.25-300 ng/g in the brain homogenate. Precision and accuracy were within the acceptance range. The method was applied to pharmacokinetics and brain uptake studies, which showed that pimavanserin penetrates the blood-brain barrier and reaches a Cmax of 21.9 ± 6.66 ng/g in 2.0 h. We also found that pimavanserin brain to plasma ratio (Kbrain/plasma) is 0.16 ± 0.05 and it is rapidly eliminated.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE