Quantification of Motor Function in Huntington Disease Patients Using Wearable Sensor Devices.
Quantification of Motor Function in Huntington Disease Patients Using Wearable Sensor Devices.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
US · Author affiliation · country only
Specialty Clinical Development, Teva Pharmaceutical Industries Ltd., Frazer, Pennsylvania, USA.Location evidence
JE · Author affiliation · country only
Guide Pharmaceutical Consulting, LLC, Millstone Township, New Jersey, USA.Location evidence
IL · Author affiliation · country only
Advanced Analytics Department, Intel, Petah Tikva, Israel.Location evidence
Münster, DE · Author affiliation
George Huntington Institute and Department of Radiology University of Münster, Münster, Germany.Location evidence
Tübingen, DE · Author affiliation
Department of Neurodegenerative Diseases and Hertie Institute for Clinical Brain Research, University of Tübingen, Tübingen, Germany.Location evidence
New Orleans, US · Author affiliation
Specialty Research and Development, Teva Pharmaceutical Industries Ltd., New Orleans, Louisiana, USA.Location evidence
Herzliya, IL · Author affiliation
Data Science Institute, Interdisciplinary Center, Herzliya, Israel.Location evidence
Netanya, IL · Author affiliation
Clinical Operations, Biometrics and Data Science, Netanya, Israel.Location evidence
Boston, US · Author affiliation
Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, USA.Location evidence
Basel, CH · Author affiliation
Teva Pharmaceuticals International, Basel, Switzerland.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Previous studies have demonstrated the feasibility and promise of wearable sensors as objective measures of motor impairment in Parkinson disease and essential tremor. However, there are few published studies that have examined such an application in Huntington disease (HD). This report provides an evaluation of the potential to objectively quantify chorea in HD patients using wearable sensor data. Data were derived from a substudy of the phase 2 Open-PRIDE-HD study, where 17 patients were screened and 15 patients enrolled in the substudy and ultimately 10 patients provided sufficient wearable sensor data. The substudy was designed to provide high-resolution data to inform design of predictive algorithms for chorea quantification. During the entire course of the 6-month study, in addition to chorea ratings from 18 in-clinic assessments, 890 home assessments, and 1,388 responses to daily reminders, 33,000 h of high-resolution accelerometer data were captured continuously from wearable smartwatches and smartphones. Despite its limited sample size, our study demonstrates that arm chorea can be characterized using accelerometer data during static assessments. Nonetheless, the small sample size limits the generalizability of the model. The sensor-based model can quantify the chorea level with high correlation to the chorea severity reported by both clinicians and patients. In addition, our analysis shows that the chorea digital signature varies between patients. This work suggests that digital wearable sensors have the potential to support clinical development of medications in patients with movement disorders, such as chorea. However, additional data would be needed from a larger number of HD patients with a full range of chorea severity (none to severe) with and without intervention to validate this potentially predictive technology.