RESEARCH / DISCOVERY
← Back to the library

Flexible platinum electrodes as electrochemical sensor and immunosensor for Parkinson's disease biomarkers.

Flexible platinum electrodes as electrochemical sensor and immunosensor for Parkinson's disease biomarkers.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

São Carlos, BR · Author affiliation

Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil.
Location evidence

Araras, BR · Author affiliation

Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil.
Location evidence

São Paulo, BR · Author affiliation

Bioanalysis, Microfluidics and Separation Group, São Carlos Institute of Chemistry, University of São Paulo, 13566-590, São Carlos, SP, Brazil.
Location evidence

São José dos Campos, BR · Author affiliation

Institute of Science and Technology, Federal University of São Paulo, 12231-280, São José dos Campos, SP, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

In this study, platinum electrodes were fabricated on the bio-based poly(ethylene terephthalate) (Bio-PET) substrates for the development of flexible electrochemical sensors for the detection of Parkinson's disease biomarkers. Dopamine was detected by voltammetric measurements, displaying a 3.5 × 10-5 mol L-1 to 8.0 × 10-4 mol L-1 linear range with a limit of detection of 5.1 × 10-6 mol L-1. Parkinson's disease protein 7 (PARK7/DJ-1) was successfully detected by electrochemical impedance spectroscopy after electrode functionalization with specific anti-PARK7/DJ-1 antibodies. In this case, analytical curves presented a linear behavior from 40 ng mL-1 to 150 ng mL-1 of PARK7/DJ-1 with a limit of detection of 7.5 ng mL-1. Besides, the electrodes did not suffer any change in the electrochemical response after manual tests of mechanical tension. The proposed sensor and immunosensor were applied for the determination of Parkinson's disease biomarkers concentrations found in the human body, being adequate as an alternative method to diagnose this disease.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE