Bipolar Directional Deep Brain Stimulation in Essential and Parkinsonian Tremor.

Bipolar Directional Deep Brain Stimulation in Essential and Parkinsonian Tremor.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

DE · Author affiliation · country only

Faculty of Medicine and University Hospital Cologne, Department of Neurology, University of Cologne, Cologne, Germany.
Location evidence

Jülich, DE · Author affiliation

Cognitive Neuroscience, Institute of Neuroscience and Medicine (INM-3), Research Center Jülich, Jülich, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: To compare directional monopolar, bipolar, and directional bipolar thalamic deep brain stimulation (DBS) in tremor patients. METHODS: Fourteen tremor patients (7 Essential Tremor and 7 Parkinson's Disease) implanted with directional DBS electrodes in the ventral intermediate nucleus (VIM) were enrolled. Side-effect thresholds of monopolar directional stimulation (DIRECT) were compared to circular DBS as well as, in a randomized design, to those of two different bipolar stimulation settings (BIPOLAR = circular anode; BI-DIRECT = directional anode). Tremor suppression (Tremor Rating Scale, TRS) right below the side-effect threshold was also assessed. RESULTS: Directional DBS in the individually best direction showed higher side-effect thresholds than circular DBS (p = 0.0063). The thresholds were raised further using either one of the bipolar stimulation paradigms (BIPOLAR p = 0.0029, BI-DIRECT p = 0.0022). The side-effect thresholds did not differ between both bipolar settings, but side-effects were less frequent with BI-DIRECT. No difference in TRS scores with stimulation just below the side-effect threshold was found between all stimulation conditions. CONCLUSIONS: Side-effect thresholds of monopolar directional and bipolar stimulation with both circular and directional anodes were higher compared to traditional monopolar circular stimulation in the VIM. Bipolar DBS with directional anodes evoked side-effect less frequently than bipolar and monopolar directional stimulation. All stimulation settings had comparable effects on tremor suppression just below their side-effect thresholds. Thus, directional and different bipolar settings should be explored in patients with bothersome side-effects of thalamic stimulation when monopolar stimulation settings are not satisfying. Further studies are needed to explore the efficiency of the different bipolar stimulation paradigms.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE