RESEARCH / DISCOVERY
← Back to the library

A new detection method for EMG activity monitoring.

A new detection method for EMG activity monitoring.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Algiers, DZ · Author affiliation

Laboratoire Traitement du Signal, Ecole Militaire Polytechnique, Algiers, Algeria. bengacemihichem@yahoo.fr.
Location evidence

Orléans, FR · Author affiliation

PRISME Laboratory, University of Orléans, 12 Rue de Blois, 45067, Orléans, France. bengacemihichem@yahoo.fr.
Location evidence

Blois, FR · Author affiliation

PRISME Laboratory, University of Orléans, 12 Rue de Blois, 45067, Orléans, France. bengacemihichem@yahoo.fr.
Location evidence

Mostaganem, DZ · Author affiliation

Laboratoire Signaux et Systemes, Université de Mostaganem, Mostaganem, Algeria.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

This paper introduces a new approach for electromyography (EMG) activity monitoring based on an improved version of the adaptive linear energy detector (ALED), a widely used technique in voice activity detection. More precisely, we propose a modified ALED technique (named M-ALED) to improve the method's robustness with respect to noise. To achieve this objective, M-ALED relies on the Teager-Kaiser operator for signal pre-conditioning to increase the SNR and uses the order statistics to gain robustness against the signal's impulsiveness. We propose again to exploit the order statistics for the initial signal baseline estimation to deal with the cases where such information is unavailable. Finally, since M-ALED detects the signal's activity at the frame level, we propose in a second stage to refine this detection (at the sample level) by using a constant false alarm rate (CFAR) approach leading to the fine M-ALED (FM-ALED) solution. The performance of FM-ALED is assessed via real and synthetic EMG signal recordings and the obtained results highlight its effectiveness as compared with the state-of-the-art methods (it reduces the mean error probability by a factor close to 2).