Improved detection of Parkinsonian resting tremor with feature engineering and Kalman filtering.
Improved detection of Parkinsonian resting tremor with feature engineering and Kalman filtering.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Ithaca, US · Author affiliation
ECE Department, Cornell University, Ithaca, NY, USA. Electronic address: ly329@cornell.edu.Location evidence
Oxford, GB · Author affiliation
Medical Research Council Brain Network Dynamics Unit, University of Oxford, Oxford, UK; Nuffield Department of Clinical Neurosciences, John Radcliffe Hospital, University of Oxford, Oxford, UK.Location evidence
Radcliffe, GB · Author affiliation
Medical Research Council Brain Network Dynamics Unit, University of Oxford, Oxford, UK; Nuffield Department of Clinical Neurosciences, John Radcliffe Hospital, University of Oxford, Oxford, UK.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
OBJECTIVE: Accurate and reliable detection of tremor onset in Parkinson's disease (PD) is critical to the success of adaptive deep brain stimulation (aDBS) therapy. Here, we investigated the potential use of feature engineering and machine learning methods for more accurate detection of rest tremor in PD. METHODS: We analyzed the local field potential (LFP) recordings from the subthalamic nucleus region in 12 patients with PD (16 recordings). To explore the optimal biomarkers and the best performing classifier, the performance of state-of-the-art machine learning (ML) algorithms and various features of the subthalamic LFPs were compared. We further used a Kalman filtering technique in feature domain to reduce the false positive rate. RESULTS: The Hjorth complexity showed a higher correlation with tremor, compared to other features in our study. In addition, by optimal selection of a maximum of five features with a sequential feature selection method and using the gradient boosted decision trees as the classifier, the system could achieve an average F1 score of up to 88.7% and a detection lead of 0.52 s. The use of Kalman filtering in feature space significantly improved the specificity by 17.0% (p = 0.002), thereby potentially reducing the unnecessary power dissipation of the conventional DBS system. CONCLUSION: The use of relevant features combined with Kalman filtering and machine learning improves the accuracy of tremor detection during rest. SIGNIFICANCE: The proposed method offers a potential solution for efficient on-demand stimulation for PD tremor.