RESEARCH / DISCOVERY
← Back to the library

STrategically Acquired Gradient Echo (STAGE) imaging, part III: Technical advances and clinical applications of a rapid multi-contrast multi-parametric brain imaging method.

STrategically Acquired Gradient Echo (STAGE) imaging, part III: Technical advances and clinical applications of a rapid multi-contrast multi-parametric brain imaging method.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Detroit, US · Author affiliation

Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA; The MRI Institute for Biomedical Research, Bingham Farms, MI, USA; Magnetic Resonance Innovations, Inc., Bingham Farms, MI, USA. Electronic address: nmrimaging@aol.com.
Location evidence

US · Author affiliation · country only

The MRI Institute for Biomedical Research, Bingham Farms, MI, USA; Magnetic Resonance Innovations, Inc., Bingham Farms, MI, USA.
Location evidence

Shanghai, CN · Author affiliation

Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China; Neusoft Medical Systems Co., Ltd., Shanghai, China.
Location evidence

Tianjin, CN · Author affiliation

Department of Radiology, Tianjin First Central Hospital, Tianjin, China.
Location evidence

Zhengzhou, CN · Author affiliation

Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Location evidence

Milan, IT · Author affiliation

IRCCS, Fondazione Don Carlo Gnocchi ONLUS, Milano, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

One major thrust in radiology today is image standardization with a focus on rapidly acquired quantitative multi-contrast information. This is critical for multi-center trials, for the collection of big data and for the use of artificial intelligence in evaluating the data. Strategically acquired gradient echo (STAGE) imaging is one such method that can provide 8 qualitative and 7 quantitative pieces of information in 5 min or less at 3 T. STAGE provides qualitative images in the form of proton density weighted images, T1 weighted images, T2* weighted images and simulated double inversion recovery (DIR) images. STAGE also provides quantitative data in the form of proton spin density, T1, T2* and susceptibility maps as well as segmentation of white matter, gray matter and cerebrospinal fluid. STAGE uses vendors' product gradient echo sequences. It can be applied from 0.35 T to 7 T across all manufacturers producing similar results in contrast and quantification of the data. In this paper, we discuss the strengths and weaknesses of STAGE, demonstrate its contrast-to-noise (CNR) behavior relative to a large clinical data set and introduce a few new image contrasts derived from STAGE, including DIR images and a new concept referred to as true susceptibility weighted imaging (tSWI) linked to fluid attenuated inversion recovery (FLAIR) or tSWI-FLAIR for the evaluation of multiple sclerosis lesions. The robustness of STAGE T1 mapping was tested using the NIST/NIH phantom, while the reproducibility was tested by scanning a given individual ten times in one session and the same subject scanned once a week over a 12-week period. Assessment of the CNR for the enhanced T1W image (T1WE) showed a significantly better contrast between gray matter and white matter than conventional T1W images in both patients with Parkinson's disease and healthy controls. We also present some clinical cases using STAGE imaging in patients with stroke, metastasis, multiple sclerosis and a fetus with ventriculomegaly. Overall, STAGE is a comprehensive protocol that provides the clinician with numerous qualitative and quantitative images.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE