RESEARCH / DISCOVERY
← Back to the library

Wearable Sensors for Estimation of Parkinsonian Tremor Severity during Free Body Movements.

Wearable Sensors for Estimation of Parkinsonian Tremor Severity during Free Body Movements.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Boca Raton, US · Author affiliation

Department of Computer and Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA. mhssayeni2017@fau.edu.
Location evidence

New York City, US · Author affiliation

Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA. Joohi.Jimenez-shahed@mountsinai.org.
Location evidence

US · Author affiliation · country only

Department of Neurology, University of Rochester Medical Center, Rochester, NY 14642, USA. MichelleBurack@youcenteredhealth.org.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Tremor is one of the main symptoms of Parkinson's Disease (PD) that reduces the quality of life. Tremor is measured as part of the Unified Parkinson Disease Rating Scale (UPDRS) part III. However, the assessment is based on onsite physical examinations and does not fully represent the patients' tremor experience in their day-to-day life. Our objective in this paper was to develop algorithms that, combined with wearable sensors, can estimate total Parkinsonian tremor as the patients performed a variety of free body movements. We developed two methods: an ensemble model based on gradient tree boosting and a deep learning model based on long short-term memory (LSTM) networks. The developed methods were assessed on gyroscope sensor data from 24 PD subjects. Our analysis demonstrated that the method based on gradient tree boosting provided a high correlation (r = 0.96 using held-out testing and r = 0.93 using subject-based, leave-one-out cross-validation) between the estimated and clinically assessed tremor subscores in comparison to the LSTM-based method with a moderate correlation (r = 0.84 using held-out testing and r = 0.77 using subject-based, leave-one-out cross-validation). These results indicate that our approach holds great promise in providing a full spectrum of the patients' tremor from continuous monitoring of the subjects' movement in their natural environment.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE