RESEARCH / DISCOVERY
← Back to the library

Test-retest reliability of stride length-cadence gait relationship in Parkinson's disease.

Test-retest reliability of stride length-cadence gait relationship in Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Alcorcón, ES · Author affiliation

King Juan Carlos University, Faculty of Sciences of Sport and Physical Education, Area of Sport Sciences, Avenida de Atenas s/n, Alcorcón, Madrid, 28992, Spain; University of A Coruña, Department of Sport Sciences, Av. Ernesto Che Guevara 112.
Location evidence

Madrid, ES · Author affiliation

King Juan Carlos University, Faculty of Sciences of Sport and Physical Education, Area of Sport Sciences, Avenida de Atenas s/n, Alcorcón, Madrid, 28992, Spain; University of A Coruña, Department of Sport Sciences, Av. Ernesto Che Guevara 112.
Location evidence

A Coruña, ES · Author affiliation

King Juan Carlos University, Faculty of Sciences of Sport and Physical Education, Area of Sport Sciences, Avenida de Atenas s/n, Alcorcón, Madrid, 28992, Spain; University of A Coruña, Department of Sport Sciences, Av. Ernesto Che Guevara 112.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: The gait pattern in Parkinson´s disease (PD) subjects is characterized by a specific deficit of the internal regulation of the stride length (SL), while the control of the cadence (Cad) remains intact. The purpose of the present study was to evaluate the reliability of the stride length-cadence relationship (SLCrel) in a group of PD subjects. METHODS: Thirty five PD subjects performed two sessions, separated by a three month resting period. In each session Gait speed, SL and Cad were evaluated at five different self-selected speed conditions: preferred, slow, very slow, fast and very fast. Linear regression analysis was used to explore the SLCrel and to determine the slope, intercept and coefficient of determination (R2) for each participant. Test-retest reliability for the slope and intercept was calculated using intra-class correlation coefficient (ICC), 95% confidence interval (CI), and standard error of mean (SEM). RESULTS: There were no significant differences in the slope and intercept between the two sessions. The overall speed was significantly faster in the second session compared with the first one (F = 4.60, p = 0.03). The SLCrel showed high reliability across the sessions (ICC = 0.89 and ICC = 0.91; 95% CI = 0.80-0.95 and 95% CI = 0.82-0.95; SEM = 0.002 and SEM = 0.073, for the slope and interception, respectively). CONCLUSIONS: The SLCrel in Parkinsonian gait is a reproducible measure across a period of three months, and may be a useful tool to explore the specificity of gait rehabilitation interventions in PD subjects.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE