Adenosine-sensitive decremental conduction over short non-decremental atrioventricular accessory pathways after radiofrequency ablation: case series.

Adenosine-sensitive decremental conduction over short non-decremental atrioventricular accessory pathways after radiofrequency ablation: case series.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Bochum, DE · Author affiliation

Division of Clinical Electrophysiology, Department of Cardiology and Angiology, Augusta-Kranken-Anstalt, Bergstr. 26, Bochum, Germany.
Location evidence

Witten, DE · Author affiliation

Witten-Herdecke University, Alfred-Herrhausen-Straße 50, Witten, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Decremental conduction in short anterograde atrioventricular accessory pathways (AV-APs) is rare. CASE PRESENTATION: We report on two cases with radiofrequency (RF) ablation of anterograde fast non-decremental AV-AP conduction. In Case 1, electrophysiological testing revealed fast non-decremental conduction over an anterograde short right posteroseptal AV-AP. During ablation, latent pre-excitation due to anterograde adenosine-sensitive slow decremental conduction over the same AV-AP manifested after eliminating its non-decremental conduction. Complete abolition of AP conduction was achieved by additional ablation. In Case 2, overt pre-excitation disappeared after the first ablation session for an anterograde short non-decremental right mid-septal AV-AP. However, latent pre-excitation due to markedly decremental conduction over the same AV-AP unmasked by intravenous adenosine and atrial pacing manoeuvers could be eliminated in a second session. DISCUSSION: This report describes unusual anterograde short non-decremental AV-APs, developing markedly slow adenosine-sensitive decremental conduction during ablation. Such AV-AP conduction properties due to RF injury may be overlooked and mask incomplete ablation and point-out careful testing including stimulation techniques and low and higher dose adenosine administration post-ablation.