Smartwatch for the analysis of rest tremor in patients with Parkinson's disease.
Smartwatch for the analysis of rest tremor in patients with Parkinson's disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Madrid, ES · Author affiliation
Healthcare Research Institute (i+12), Hospital Universitario 12 de Octubre, Madrid, Spain; Neurology Section, Hospital Virgen de la Poveda, Villa del Prado, Madrid, Spain; Medicine Department, Faculty of Medicine, Universidad Complutense Madrid (UCM), Spain. Electronic address: robretolb@gmail.com.Location evidence
Universidad, ES · Author affiliation
Healthcare Research Institute (i+12), Hospital Universitario 12 de Octubre, Madrid, Spain; Neurology Section, Hospital Virgen de la Poveda, Villa del Prado, Madrid, Spain; Medicine Department, Faculty of Medicine, Universidad Complutense Madrid (UCM), Spain. Electronic address: robretolb@gmail.com.Location evidence
Centro, ES · Author affiliation
Neural and Cognitive Engineering Group, Centro de Automática y Robótica (CAR), CSIC-UPM, Madrid, Spain.Location evidence
Pozuelo de Alarcón, ES · Author affiliation
Faculty of Biosanitary Sciences, Francisco de Vitoria University, Pozuelo de Alarcón, Madrid, Spain; Brain Damage Service, Hospital Beata Maria Ana, Madrid, Spain.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Wearable technology used in Parkinson's disease (PD) research has become an increasing focus of interest in this field. Our group assessed the feasibility, clinical correlation, reliability, and acceptance of smartwatches in order to quantify arm resting tremors in PD patients. An Android application on a smartwatch was used to obtain raw data from the smartwatch's gyroscopes. Twenty-two PD patients were consecutively recruited and followed for 1 year. Arm rest tremors were video filmed and scored by two independent raters using the motor subscale of the Unified Parkinson's Disease Rating Scale (UPDRS-III). The tremor intensity parameter was defined by the root mean square of the angular speed measured by the smartwatch at the wrist. Sixty-four smartwatch evaluations were completed. The Spearman coefficient among the mean of the resting tremor (UPDRS-III) scores and smartwatch measurements for tremor intensity was 0.81 (p < .001); smartwatch reliability to quantify tremors was checked by intraclass reliability coefficient with a resting tremor = 0.89, minimum detectable change = 59.03%. Good acceptance of the system was shown. Smartwatch use for PD tremor analysis is possible, reliable, well-correlated with clinical scores, and well-accepted by patients for clinical follow-up. The results from these experiments suggest that this commodity hardware has the potential to quantify PD patients' tremors objectively in a consulting-room.