Clinical feasibility of a wearable, conformable sensor patch to monitor motor symptoms in Parkinson's disease.
Clinical feasibility of a wearable, conformable sensor patch to monitor motor symptoms in Parkinson's disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Monheim am Rhein, DE · Author affiliation
UCB Pharma, Monheim am Rhein, Germany. Electronic address: Babak.Boroojerdi@ucb.com.Location evidence
US · Author affiliation · country only
MC10 Inc., Lexington, MA, USA. Electronic address: rooz@northwestern.edu.Location evidence
Raleigh, US · Author affiliation
UCB Pharma, Raleigh, NC, USA. Electronic address: Michael.Markowitz@ucb.com.Location evidence
Brussels, BE · Author affiliation
UCB Pharma, Brussels, Belgium. Electronic address: Christian.Otoul@ucb.com.Location evidence
Bulle, CH · Author affiliation
UCB Medical Devices, Bulle, Switzerland. Electronic address: Oliver.Stumpp@ucb.com.Location evidence
Slough, GB · Author affiliation
UCB Pharma, Slough, UK. Electronic address: terricabras.dolors@gmail.com.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
INTRODUCTION: Clinical assessment of motor symptoms in Parkinson's disease (PD) is subjective and may not reflect patient real-world experience. This two-part pilot study evaluated the accuracy of the NIMBLE wearable biosensor patch (containing an accelerometer and electromyography sensor) to record body movements in clinic and home environments versus clinical measurement of motor symptoms. METHODS: Patients (Hoehn & Yahr 2-3) had motor symptom fluctuations and were on a stable levodopa dose. Part 1 investigated different sensor body locations (six patients). In Part 2, 21 patients wore four sensors (chest, and most affected side of shin, forearm and back-of-hand) during a 2-day clinic- and 1-day home-based evaluation. Patients underwent Unified Parkinson's Disease Rating Scale assessments on days 1-2, and performed pre-defined motor activities at home on day 3. An algorithm estimated motor-symptom severity (predicted scores) using patch data (in-clinic); this was compared with in-clinic motor symptom assessments (observed scores). RESULTS: The overall correlation coefficient between in-clinic observed and sensor algorithm-predicted scores was 0.471 (p = 0.031). Predicted and observed scores were identical 45% of the time, with a predicted score within a ±1 range 91% of the time. Exact accuracy for each activity varied, ranging from 32% (pronation/supination) to 67% (rest-tremor-amplitude). Patients rated the patch easy-to-use and as providing valuable data for managing PD symptoms. Overall patch-adhesion success was 97.2%. The patch was safe and generally well tolerated. CONCLUSIONS: This study showed a correlation between sensor algorithm-predicted and clinician-observed motor-symptom scores. Algorithm refinement using patient populations with greater symptom-severity range may potentially improve the correlation.