RESEARCH / DISCOVERY
← Back to the library

A baseline study for detection of Parkinson's disease with 3D-transcranial sonography and uni-lateral reconstruction.

A baseline study for detection of Parkinson's disease with 3D-transcranial sonography and uni-lateral reconstruction.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Munich, DE · Author affiliation

Department of Neurology, Ludwig-Maximilians-University, Marchioninistr. 15, 81667 Munich, Germany. Electronic address: Annika.Plate@med.uni-muenchen.de.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: TCS is a well-established technique for diagnosis of Parkinson's disease (PD). Volumetric 3D-TCS is a promising complementary approach for objective acquisition and analysis, in particular for less experienced sonographers. This study provides baselines for Parkinson detection (sensitivity and specificity), cutoff values and inter-rater agreement in 3D-TCS. METHODS: We performed 3D-TCS in 52 subjects (healthy controls and PD) bilaterally, and reconstructed in 3D space uni-laterally. Ipsi-lateral hyperechogenicities in the substantia nigra are manually segmented slice-by-slice in the 3D volume by two raters at different experience levels. ROC threshold analysis is performed and compared on features representing 3D volume and axial cross-sections (2.5D) of hyperechogenicities. Pearson correlation and intra-class correlation coefficients were evaluated for assessment of inter-rater agreement. RESULTS: 50 subjects were included. Both raters achieved high classification accuracy with 2.5D/3D features extracted from 3D-TCS volumes (best results sensitivity/specificity/cut-off per rater: 84.6%/88.9%/25.0mm2; 77.8%/88.9%/95.9mm3). The inter-rater agreement in 3D was high (ICC(A,1) = 0.777, p < 10-3), the classification performance of both sonographers was statistically not significantly different. CONCLUSION: The study presents first baseline values for uni-lateral 3D-TCS examination, and finds no disadvantage of uni-lateral reconstructions compared to previous bi-lateral fusion. Volumetric 3D-TCS has potential for a high inter-rater agreement and accuracy in detection of PD, in particular for sonographers with less experience.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE