RESEARCH / DISCOVERY
← Back to the library

Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples.

Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Ribeirão Preto, BR · Author affiliation

Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil.
Location evidence

São Paulo, BR · Author affiliation

Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil.
Location evidence

BR · Author affiliation · country only

Instituto de Química, Universidade Estadual de Campinas, Campinas, SP, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

This manuscript describes the development of wall-coated open tubular capillary column with polymeric ionic liquids (PILs) for on-line in-tube solid phase microextraction coupled with ultra high-performance liquid chromatography tandem mass spectrometry (in-tube SPME/UHPLC-MS/MS) to determine anandamide (AEA) and 2-arachidonoyl glycerol (2 A G) in plasma samples. Selective PILs were synthetized from the [VC6IM][Cl], [VC16IM][Br], and [(VIM)2C10]2 [Br] - ionic liquids - by in-situ thermal-initiated polymerization in a fused silica capillary column for in-tube SPME. The synthesis procedure was optimized, and the capillary columns were characterized using spectroscopic and chromatography techniques. The chemically bonded and cross-linked PIL-based sorbent phase (thickness coating: 1.7 μm) presented high chemical and mechanical stability. Among the sorbents evaluated, the PIL-based capillary, [VC16IM][Br]/[(VIM)2C10]2 [Br] presented the best performance with a sorption capacity of 37,311 ng cm-3 and 48,307 ng cm-3 for AEA and 2 A G, respectively. This capillary was reused more than ninety times without significant changes in extraction efficiency. The in-tube SPME-UHPLC-MS/MS method presented a linear range from 0.1 ng mL-1 to 100 ng mL-1 for AEA, and from 0.05 ng mL-1 to 100 ng mL-1 for 2 A G, with coefficients of determination higher than 0.99, p-value for Lack-of-fit test higher than 0.05 (α of 0.05), precision with coefficient of variation (CV) values ranging from 1.6 to 14.0% and accuracy with relative standard deviation (RSD) values from -19.6% to 13.2%. This method was successfully applied to determine AEA and 2 A G in plasma patients with Parkinson's disease. The concentrations in these plasma samples ranged from 0.14 to 0.46 ng mL-1 for AEA and from <0.05 ng mL-1 to 0.51 ng mL-1 for 2-AG.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE