RESEARCH / DISCOVERY
← Back to the library

Is the Munich dysphagia Test-Parkinson's disease (MDT-PD) a valid screening tool for patients at risk for aspiration?

Is the Munich dysphagia Test-Parkinson's disease (MDT-PD) a valid screening tool for patients at risk for aspiration?

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Hamburg, DE · Author affiliation

Center for Clinical Neurosciences, Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Electronic address: buhmann@uke.de.
Location evidence

Augsburg, DE · Author affiliation

Center for Clinical Neurosciences, Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Clinic for Neurology and Neurophysiology, Klinikum Augsburg, Augsburg, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Dysphagia is common in Parkinson's disease (PD) and leads to pneumonia, malnutrition, and reduced quality of life. For detecting dysphagia-exposed PD patients, the Munich dysphagia test-Parkinson's disease (MDT-PD) is a patient self-reported tool that has been developed specifically for PD patients. The MDT-PD is available in both German and English. This study aimed to ascertain whether the MDT-PD can detect aspiration in PD patients and, therefore, serve as a suitable screening tool. METHODS: In a controlled, cross-sectional, observational study, a total of 119 PD outpatients were examined clinically and were evaluated by the MDT-PD and the one swallowing question (NMS-3) from the nonmotor symptom questionnaire for Parkinson's disease (NMSQuest). The results of the MDT-PD and the NMS-3 were compared to the penetration-aspiration scale (PAS) rating defined by flexible endoscopic evaluation of swallowing (FEES). KEY RESULTS: Half of the patients with aspiration as determined using FEES were not detected by the MDT-PD and NMS-3 self-reported tools. The proportion of false positive patients was high with both tools. The sensitivity of the MDT-PD to detect patients who are at risk for aspiration is insufficient (0.37) and not superior to applying the dysphagia screening question from the NMSQuest (0.5). CONCLUSION: This study reveals that the MDT-PD is not suitable for detecting aspiration in PD patients and, therefore, cannot be considered as a screening tool for aspiration. However, at present, there is no alternative validated screening tool that can reliably detect aspiration in PD patients. A readjustment of the MDT-PD is urgently needed.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE